CoChat

Simple, rapid spectrophotometry of urinary N-acetyl-beta-D-glucosaminidase, with use of a new chromogenic substrate.

Noto, A, Ogawa, Y, Mori, S, Yoshioka, M, Kitakaze, T, Hori, T, Nakamura, M, Miyake, T · 1983 · Clinical Chemistry
Cited by 170

The DOI matches its Crossref record.

Abstract

We have developed a new spectrophotometric assay for urinary N-acetyl-beta-D-glucosaminidase (NAGase) with use of sodio m-cresolsulfonphthaleinyl N-acetyl-beta-D-glucosaminide (MCP-NAG). MCP-NAG was synthesized from acetochloro-glucosamine and m-cresolsulfonphthalein (MCP) in four steps. MCP-NAG reacts well with NAGase (Km = 0.41 mmol/L) and is highly water soluble. The absorption maximum and molar absorptivity of the aglycone MCP are 580 nm and 40 670, respectively. Spectral overlap of interfering substances at 580 nm is almost negligible, so that the urine blank can be omitted from the assay procedure. The high molar absorptivity of MCP gives sufficient analytical sensitivity at a reaction time of 15 min. The correlation between the MCP-NAG method (y) and the fluorimetric method (x) involving 4-methylumbelliferyl N-acetyl-beta-D-glucosaminide is represented by the equation y = 0.995x - 0.669 (r = 0.991). Thus, the present method provides practical advantages over conventional methods, for use in the routine laboratory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/29.10.1713

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
Noto, A., Ogawa, Y., Mori, S., Yoshioka, M., Kitakaze, T., Hori, T., Nakamura, M., & Miyake, T.
Venue
Clinical Chemistry
Published
1983-10-01
Volume
29
Issue
10
Pages
1713-1716
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1893661533
Cited by
170
References
0
FWCI
3.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simple, rapid spectrophotometry of urinary N-acetyl-beta-D-glucosaminidase, with use of a new chromogenic substrate. https://app.cochat.ai/papers/10.1093/clinchem/29.10.1713
The paper
Noto, A., Ogawa, Y., Mori, S., Yoshioka, M., Kitakaze, T., Hori, T., Nakamura, M., & Miyake, T. (1983). Simple, rapid spectrophotometry of urinary N-acetyl-beta-D-glucosaminidase, with use of a new chromogenic substrate. Clinical Chemistry. https://doi.org/10.1093/clinchem/29.10.1713

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.