The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fluoro‐Photoacoustic Polymeric Renal Reporter for Real‐Time Dual Imaging of Acute Kidney Injury
Abstract
Photoacoustic (PA) imaging agents detect disease tissues and biomarkers with increased penetration depth and enhanced spatial resolution relative to traditional optical imaging, and thus hold great promise for clinical applications. However, existing PA imaging agents often encounter the issues of slow body excretion and low‐signal specificity, which compromise their capability for in vivo detection. Herein, a fluoro‐photoacoustic polymeric renal reporter (FPRR) is synthesized for real‐time imaging of drug‐induced acute kidney injury (AKI). FPRR simultaneously turns on both near‐infrared fluorescence (NIRF) and PA signals in response to an AKI biomarker (γ‐glutamyl transferase) with high sensitivity and specificity. In association with its high renal clearance efficiency (78% at 24 h post‐injection), FPRR can detect cisplatin‐induced AKI at 24 h post‐drug treatment through both real‐time imaging and optical urinalysis, which is 48 h earlier than serum biomarker elevation and histological changes. More importantly, the deep‐tissue penetration capability of PA imaging results in a signal‐to‐background ratio that is 2.3‐fold higher than NIRF imaging. Thus, the study not only demonstrates the first activatable PA probe for real‐time sensitive imaging of kidney function at molecular level, but also highlights the polymeric probe structure with high renal clearance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of nanoparticle design for overcoming biological barriers to drug delivery
Blanco, E., Shen, H., & Ferrari, M. (2015) · Nature Biotechnology · doi:10.1038/nbt.3330 · Cited by 7,002
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Applications of MALDI Mass Spectrometry in Clinical Chemistry
Duncan, M. W., Nedelkov, D., Walsh, R., & Hattan, S. J. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.239491 · Cited by 96
Cited by
Xu, M., Qi, Y., Liu, G., Song, Y., Jiang, X., & Du, B. (2023) · ACS Nano · doi:10.1021/acsnano.3c05853 · Cited by 632
Fluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Hemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Self-citationTan, J., Yin, K., Ouyang, Z., Wang, R., Pan, H., Wang, Z., Zhao, C., Guo, W., & Gu, X. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03926 · Cited by 52
Chen, J., Chen, L., Fang, Y., Zeng, F., & Wu, S. (2022) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2021.100570 · Cited by 29
Metadata
- Authors
- Cheng, P., Chen, W., Li, S., He, S., Miao, Q., & Pu, K.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2020-03-06
- Volume
- 32
- Issue
- 17
- Pages
- e1908530-e1908530
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3009776436
- Cited by
- 161
- References
- 4
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluoro‐Photoacoustic Polymeric Renal Reporter for Real‐Time Dual Imaging of Acute Kidney Injury. https://app.cochat.ai/papers/10.1002/adma.201908530
- The paper
- Cheng, P., Chen, W., Li, S., He, S., Miao, Q., & Pu, K. (2020). Fluoro‐Photoacoustic Polymeric Renal Reporter for Real‐Time Dual Imaging of Acute Kidney Injury. Advanced Materials. https://doi.org/10.1002/adma.201908530
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.