Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Fluoro‐Photoacoustic Polymeric Renal Reporter for Real‐Time Dual Imaging of Acute Kidney Injury

Cheng, Penghui, Chen, Wan, Li, Shenhua, He, Shasha, Miao, Qingqing, Pu, Kanyi·2020·Advanced Materials

Abstract

Photoacoustic (PA) imaging agents detect disease tissues and biomarkers with increased penetration depth and enhanced spatial resolution relative to traditional optical imaging, and thus hold great promise for clinical applications. However, existing PA imaging agents often encounter the issues of slow body excretion and low‐signal specificity, which compromise their capability for in vivo detection. Herein, a fluoro‐photoacoustic polymeric renal reporter (FPRR) is synthesized for real‐time imaging of drug‐induced acute kidney injury (AKI). FPRR simultaneously turns on both near‐infrared fluorescence (NIRF) and PA signals in response to an AKI biomarker (γ‐glutamyl transferase) with high sensitivity and specificity. In association with its high renal clearance efficiency (78% at 24 h post‐injection), FPRR can detect cisplatin‐induced AKI at 24 h post‐drug treatment through both real‐time imaging and optical urinalysis, which is 48 h earlier than serum biomarker elevation and histological changes. More importantly, the deep‐tissue penetration capability of PA imaging results in a signal‐to‐background ratio that is 2.3‐fold higher than NIRF imaging. Thus, the study not only demonstrates the first activatable PA probe for real‐time sensitive imaging of kidney function at molecular level, but also highlights the polymeric probe structure with high renal clearance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201908530

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 161

Metadata

Authors
Cheng, P., Chen, W., Li, S., He, S., Miao, Q., & Pu, K.
Venue
Advanced Materials
Publisher
Wiley
Published
2020-03-06
Volume
32
Issue
17
Pages
e1908530-e1908530
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3009776436
Cited by
161
References
4
FWCI
16.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluoro‐Photoacoustic Polymeric Renal Reporter for Real‐Time Dual Imaging of Acute Kidney Injury. https://app.cochat.ai/papers/10.1002/adma.201908530
The paper
Cheng, P., Chen, W., Li, S., He, S., Miao, Q., & Pu, K. (2020). Fluoro‐Photoacoustic Polymeric Renal Reporter for Real‐Time Dual Imaging of Acute Kidney Injury. Advanced Materials. https://doi.org/10.1002/adma.201908530

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.