The DOI matches its Crossref record.
Radioenzymic determination of homocysteine in plasma and urine.
Abstract
Using a modification of the radioenzymic assay described previously (J Biol Chem 259: 2360-2364, 1984) we measured homocysteine in freshly prepared plasma and urine from volunteers. The concentration of free homocysteine--i.e., the amount measurable in plasma after deproteinization by strong acid--was 2.27 (SEM 0.11) mumol/L for 18 men and 1.95 (SEM 0.13) mumol/L for 16 women (p greater than 0.05, not significant). About 70% of the total homocysteine in human plasma was associated with plasma proteins, and was precipitated with strong acid. The concentration of protein-bound homocysteine in plasma was 6.51 (SEM 0.32) mumol/L for men and 7.29 (SEM 0.65) mumol/L for women, a significantly (p less than 0.01) different spread. Homocysteine was rapidly released from plasma proteins in the presence of a reducing agent, dithioerythritol. By gel filtration of plasma on a "high-performance" liquid-chromatographic column, albumin was shown to be the sole carrier of homocysteine in plasma. Because the fraction bound to protein as determined by this procedure equaled that obtained by precipitation of plasma proteins with acid, we conclude that homocysteine is bound to albumin in vivo. The concentration of homocysteine in urine ranged from 3.5 to 9.5 mumol/L, about 6 mumol of homocysteine being excreted per 24 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Self-citationFacts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Self-citationRapid high-performance liquid chromatographic assay for total homocysteine levels in human serum
Ubbink, J. B., Hayward Vermaak, W. J., & Bissbort, S. (1991) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(91)80407-4 · Cited by 678
Jacobsen, D. W., Gatautis, V. J., Green, R., Robinson, K., Savon, S. R., Secic, M., Ji, J., Otto, J. M., & Taylor, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.6.873 · Cited by 435
Folic acid—an innocuous means to reduce plasma homocysteine
Brattström, L. E., Israelsson, B., Jeppsson, J.-O., & Hultberg, B. L. (1988) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518809167487 · Cited by 363
Metadata
- Authors
- Refsum, H., Helland, S., & Ueland, P. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-04-01
- Volume
- 31
- Issue
- 4
- Pages
- 624-628
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2167491387
- Cited by
- 306
- References
- 0
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radioenzymic determination of homocysteine in plasma and urine. https://app.cochat.ai/papers/10.1093/clinchem/31.4.624
- The paper
- Refsum, H., Helland, S., & Ueland, P. M. (1985). Radioenzymic determination of homocysteine in plasma and urine. Clinical Chemistry. https://doi.org/10.1093/clinchem/31.4.624
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.