Guidelines for immunoassay data processing.
The DOI matches its Crossref record.
Abstract
These guidelines outline the minimum requirements for a data-processing package to be used in the immunoassay laboratory. They include recommendations on hardware, software, and program design. We outline the statistical analyses that should be performed to obtain the analyte concentrations of unknown specimens and to ensure adequate monitoring of within- and between-assay errors of measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective
Findlay, J. W. A., Smith, W. C., Lee, J. W., Nordblom, G. D., Das, I., DeSilva, B. S., Khan, M. N., & Bowsher, R. R. (2000) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(99)00244-7 · Cited by 589
Wang, C., Catlin, D. H., Demers, L. M., Starcevic, B., & Swerdloff, R. S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031287 · Cited by 580
The five-parameter logistic: A characterization and comparison with the four-parameter logistic
Gottschalk, P. G., & Dunn, J. R. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.035 · Cited by 449
Olsson, A., Vanderstichele, H., Andreasen, N., De Meyer, G., Wallin, A., Holmberg, B., Rosengren, L., Vanmechelen, E., & Blennow, K. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.039347 · Cited by 437
Appropriate calibration curve fitting in ligand binding assays
Findlay, J. W. A., & Dillard, R. F. (2007) · The AAPS Journal · doi:10.1208/aapsj0902029 · Cited by 379
Toward a unified approach to dose–response modeling in ecotoxicology
Ritz, C. (2010) · Environmental Toxicology and Chemistry · doi:10.1002/etc.7 · Cited by 327
Standardization of measurement of β-amyloid(1-42)in cerebrospinal fluid and plasma
Vanderstichele, H., Kerschaver, E. V., Hesse, C., Davidsson, P., Buyse, M.-A., Andreasen, N., Minthon, L., Wallin, A., Blennow, K., & Vanmechelen, E. (2000) · Amyloid · doi:10.3109/13506120009146438 · Cited by 301
A Mixture Model with Detection Limits for Regression Analyses of Antibody Response to Vaccine
Moulton, L. H., & Halsey, N. A. (1995) · Biometrics · doi:10.2307/2533289 · Cited by 159
“The lower limit may be determined routinely through the use of statistical criteria applied to estimation of the calibration curve (Rodbard, 1978; Dudley et al., 1985).”
MethodPerceived stress and physiological dysregulation in older adults
Goldman, N., Glei, D. A., Seplaki, C., Liu, I.-W., & Weinstein, M. (2005) · Stress · doi:10.1080/10253890500141905 · Cited by 80
Metadata
- Authors
- Dudley, R. A., Edwards, P., Ekins, R. P., Finney, D. J., McKenzie, I. G., Raab, G. M., Rodbard, D., & Rodgers, R. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-08-01
- Volume
- 31
- Issue
- 8
- Pages
- 1264-1271
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1937713782
- Cited by
- 288
- References
- 0
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.