The DOI matches its Crossref record.
Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer.
Abstract
In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C. This method is applicable to automated as well as manual measurements. Protein concentration and absorbance at 600 nm are linearly related throughout a wide range of concentrations, 10 to 16 000 mg/L. However, the chromogenicity of the gamma-globulins in this method is 70% of that of albumin, as estimated from results by a biuret method. Within-run CVs were less than 3.3%; the day-to-day CV was 2.9%. Errors due to interfering components in urine are less than 2%. The normal range for urinary protein as measured by this method was from 28 to 141 mg/day. Results by this method (y) and by a trichloroacetic acid-biuret method (x) correlated well (n = 80, r = 0.995; y = 0.99x - 2.9).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Differential Diagnosis of Glomerular Disease: A Systematic and Inclusive Approach
Hebert, L. A., Parikh, S., Prosek, J., Nadasdy, T., & Rovin, B. H. (2013) · American Journal of Nephrology · doi:10.1159/000354390 · Cited by 4,376
Respiratory toxicity of multi-wall carbon nanotubes
Muller, J., Huaux, F., Moreau, N., Misson, P., Heilier, J.-F., Delos, M., Arras, M., Fonseca, A., Nagy, J. B., & Lison, D. (2005) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2005.01.008 · Cited by 1,123
European Urinalysis Guidelines
Kouri, T., Fogazzi, G., Gant, V., Hallander, H., Hofmann, W., & Guder, W. G. (2000) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2000.12056993 · Cited by 384
Gansevoort, R. T., de Zeeuw, D., & de Jong, P. E. (1994) · Kidney International · doi:10.1038/ki.1994.113 · Cited by 292
How should proteinuria be detected and measured?
Lamb, E. J., MacKenzie, F., & Stevens, P. E. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009007 · Cited by 271
Metadata
- Authors
- Watanabe, N., Kamei, S., Ohkubo, A., Yamanaka, M., Ohsawa, S., Makino, K., & Tokuda, K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1986-08-01
- Volume
- 32
- Issue
- 8
- Pages
- 1551-1554
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2117871749
- Cited by
- 445
- References
- 0
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer. https://app.cochat.ai/papers/10.1093/clinchem/32.8.1551
- The paper
- Watanabe, N., Kamei, S., Ohkubo, A., Yamanaka, M., Ohsawa, S., Makino, K., & Tokuda, K. (1986). Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer. Clinical Chemistry. https://doi.org/10.1093/clinchem/32.8.1551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.