Nonspecificity of a direct 17 alpha-hydroxyprogesterone radioimmunoassay kit when used with samples from neonates.
The DOI matches its Crossref record.
Abstract
We analyzed 240 samples for 17 alpha-hydroxyprogesterone (17-OHP) with the direct-assay kit ("Coat-A-Count" method for serum samples) from Diagnostic Products Corp. (DPC). The specimens were from 50 patients with known or suspected congenital adrenal hyperplasia (CAH); 74 mostly hospitalized neonates and infants, ages three days to three months; and 116 other patients, ages six months to 23 years. Samples from the CAH group were also analyzed with our in-house assay. For 39 of the neonatal samples, the analysis with the DPC assay was repeated with re-solubilized material that had been extracted from the serum with organic solvents. Values for "17-OHP" measured with the DPC direct assay were high, not only in CAH patients, but also in many of the unaffected neonates and infants. The extraction properties of the cross-reacting immunoreactive material into various organic solvent systems were different from those of 17-OHP, and were more like those of steroid sulfates. Because of this significant cross-reactivity, we recommend that the DPC kit not be used for sera from children younger than six months of age, unless the method is modified to include an extraction step.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Xu, X., Veenstra, T. D., Fox, S. D., Roman, J. M., Issaq, H. J., Falk, R., Saavedra, J. E., Keefer, L. K., & Ziegler, R. G. (2005) · Analytical Chemistry · doi:10.1021/ac050697c · Cited by 227
Rauh, M., Gröschl, M., Rascher, W., & Dörr, H. G. (2006) · Steroids · doi:10.1016/j.steroids.2006.01.015 · Cited by 170
Caulfield, M. P., Lynn, T., Gottschalk, M. E., Jones, K. L., Taylor, N. F., Malunowicz, E. M., Shackleton, C. H. L., Reitz, R. E., & Fisher, D. A. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.8.8712 · Cited by 120
Schwarz, E., Liu, A., Randall, H., Haslip, C., Keune, F., Murray, M., Longo, N., & Pasquali, M. (2009) · Pediatric Research · doi:10.1203/pdr.0b013e3181aa3777 · Cited by 97
Janzen, N., Sander, S., Terhardt, M., Steuerwald, U., Peter, M., Das, A. M., & Sander, J. (2011) · Steroids · doi:10.1016/j.steroids.2011.07.013 · Cited by 66
Metadata
- Authors
- Makela, S. K., & Ellis, G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-10-01
- Volume
- 34
- Issue
- 10
- Pages
- 2070-2075
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2155833554
- Cited by
- 61
- References
- 0
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonspecificity of a direct 17 alpha-hydroxyprogesterone radioimmunoassay kit when used with samples from neonates. https://app.cochat.ai/papers/10.1093/clinchem/34.10.2070
- The paper
- Makela, S. K., & Ellis, G. (1988). Nonspecificity of a direct 17 alpha-hydroxyprogesterone radioimmunoassay kit when used with samples from neonates. Clinical Chemistry. https://doi.org/10.1093/clinchem/34.10.2070
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.