The DOI matches its Crossref record.
Concurrent liquid-chromatographic assay of retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in plasma, with tocopherol acetate as internal standard.
Abstract
A method is described for simultaneously determining retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in 0.25 mL of plasma. Plasma mixed with sodium dodecyl sulfate is deproteinized with ethanol containing tocopherol acetate, then extracted with heptane. The evaporated organic layer is reconstituted with mobile phase (methanol/acetonitrile/chloroform, 47/47/6 by vol) and injected onto a 100 x 4.6 mm 3-micron column of Spherisorb ODS-2 (LKB) at 1.5 mL/min. The alpha- and beta-carotenes are well resolved during the 6.5-min run. Retinol is monitored at 325 nm, the tocopherols at 292 nm, and the carotenoids at 450 nm. Extraction of concentrations as great as 135 mumol/L is complete. Intrabatch CVs were 1.7%, 2.3%, 4.1%, 10.4%, 6.4%, and 3.6% for retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin, respectively. Interbatch CVs for measurements on 30 occasions over 11 weeks were about 10% for all components except alpha-tocopherol (5.3%). Results agree well with those for retinol, alpha-tocopherol, and beta-carotene in quality-control samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bingham, S. (1997) · International Journal of Epidemiology · doi:10.1093/ije/26.suppl_1.s137 · Cited by 634
Gong, Y., Hounsa, A., Egal, S., Turner, P. C., Sutcliffe, A. E., Hall, A. J., Cardwell, K., & Wild, C. P. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.6954 · Cited by 559
Bingham, S. A., Cassidy, A., Cole, T. J., Welch, A., Runswick, S. A., Black, A. E., Thurnham, D., Bates, C., Khaw, K. T., Key, T. J. A., et al. (1995) · British Journal of Nutrition · doi:10.1079/bjn19950057 · Cited by 377
Self-citationWiseman, H., O’Reilly, J. D., Adlercreutz, H., Mallet, A. I., Bowey, E. A., Rowland, I. R., & Sanders, T. A. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.2.395 · Cited by 377
Upritchard, J. E., Sutherland, W. H., & Mann, J. I. (2000) · Diabetes Care · doi:10.2337/diacare.23.6.733 · Cited by 353
Metadata
- Authors
- Thurnham, D. I., Smith, E., & Flora, P. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-02-01
- Volume
- 34
- Issue
- 2
- Pages
- 377-381
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2140673012
- Cited by
- 382
- References
- 0
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concurrent liquid-chromatographic assay of retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in plasma, with tocopherol acetate as internal standard. https://app.cochat.ai/papers/10.1093/clinchem/34.2.377
- The paper
- Thurnham, D. I., Smith, E., & Flora, P. S. (1988). Concurrent liquid-chromatographic assay of retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in plasma, with tocopherol acetate as internal standard. Clinical Chemistry. https://doi.org/10.1093/clinchem/34.2.377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.