CoChat

Rapid equilibrium radioimmunoassay for the amino-terminal propeptide of human type III procollagen.

Risteli, J, Niemi, S, Trivedi, P, Mäentausta, O, Mowat, A P, Risteli, L · 1988 · Clinical Chemistry
Cited by 336

The DOI matches its Crossref record.

Abstract

This is an equilibrium-type radioimmunoassay for the amino-terminal propeptide of type III procollagen (PIIINP), which overcomes the problem of nonparallelism between the standard and human serum samples encountered with earlier assays. Proper selection of antiserum and reaction conditions diminishes interference from degradation products of the propeptide in serum. Because a rapid solid-phase-bound second-antibody step is included, the assay takes only 3 h. The intra-assay and the interassay CVs are both about 5%. In infants and children the concentration of PIIINP in serum closely parallels the growth-velocity curve. For 88 presumably healthy adults, the PIIINP concentration was 1.7-4.2 micrograms/L, about a third that measured with the previously available commercial assay. This is because of lack of inhibition by small Col 1 domain-related degradation products.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/34.4.715

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Risteli, J., Niemi, S., Trivedi, P., Mäentausta, O., Mowat, A. P., & Risteli, L.
Venue
Clinical Chemistry
Published
1988-04-01
Volume
34
Issue
4
Pages
715-718
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1858726777
Cited by
336
References
0
FWCI
7.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.