Effect of transport conditions on the stability of biochemical markers in blood.
The DOI matches its Crossref record.
Abstract
We examined the stability of lipids, carotenoids, alpha-tocopherol, and endogenous hormones in plasma prepared from whole blood that had been mailed to a central location for processing. Initially, to simulate transport conditions, whole-blood samples were stored in the laboratory, either at room temperature or cooled, for up to 72 h before processing. In the latter samples, lipid concentrations changed up to 1.4% per day, carotenoids up to -5.5%, and hormones up to 9.5%. In a second study, analyte concentrations in plasma from cooled whole blood mailed via overnight courier were compared with those from plasma that had been immediately separated, frozen, and mailed via overnight courier. Concentrations of cholesterol, high-density lipoprotein subfraction 3, apolipoprotein B, and retinol were stable. Overall, for each marker except estradiol, the between-person variation was at least twice the within-person variation. In a third study, at least 340 micrograms of DNA was recovered from 30 mL of cool-shipped whole blood. Our results indicate that shipping whole-blood samples by overnight courier is feasible for assay of several biochemical markers of interest in epidemiological research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Inflammatory Markers and Risk of Developing Type 2 Diabetes in Women
Hu, F. B., Meigs, J. B., Li, T. Y., Rifai, N., & Manson, J. E. (2004) · Diabetes · doi:10.2337/diabetes.53.3.693 · Cited by 788
Plasma Sex Steroid Hormone Levels and Risk of Breast Cancer in Postmenopausal Women
Hankinson, S. E., Willett, W. C., Manson, J. E., Colditz, G. A., Hunter, D. J., Spiegelman, D., Barbieri, R. L., & Speizer, F. E. (1998) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/90.17.1292 · Cited by 687
Self-citationBiomarkers of Endothelial Dysfunction and Risk of Type 2 Diabetes Mellitus
Meigs, J. B. (2004) · JAMA · doi:10.1001/jama.291.16.1978 · Cited by 643
“Quality control samples were routinely frozen with study samples; the long-term stability of plasma samples collected and stored under this protocol has been documented.(25) Study samples were analyzed in randomly ordered casecontrol pairs to further reduce systematic bias and interassay variation.”
BackgroundOrigin, Methods, and Evolution of the Three Nurses’ Health Studies
Bao, Y., Bertoia, M. L., Lenart, E. B., Stampfer, M. J., Willett, W. C., Speizer, F. E., & Chavarro, J. E. (2016) · American Journal of Public Health · doi:10.2105/ajph.2016.303338 · Cited by 556
Self-citationCalle, E. E., Rodriguez, C., Jacobs, E. J., Almon, M. L., Chao, A., McCullough, M. L., Feigelson, H. S., & Thun, M. J. (2002) · Cancer · doi:10.1002/cncr.10197 · Cited by 484
Metadata
- Authors
- Hankinson, S. E., London, S. J., Chute, C. G., Barbieri, R. L., Jones, L., Kaplan, L. A., Sacks, F. M., & Stampfer, M. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-12-01
- Volume
- 35
- Issue
- 12
- Pages
- 2313-2316
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1952381273
- Cited by
- 137
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of transport conditions on the stability of biochemical markers in blood. https://app.cochat.ai/papers/10.1093/clinchem/35.12.2313
- The paper
- Hankinson, S. E., London, S. J., Chute, C. G., Barbieri, R. L., Jones, L., Kaplan, L. A., Sacks, F. M., & Stampfer, M. J. (1989). Effect of transport conditions on the stability of biochemical markers in blood. Clinical Chemistry. https://doi.org/10.1093/clinchem/35.12.2313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.