Immunoradiometric assay of corticotropin with use of avidin-biotin separation.
The DOI matches its Crossref record.
Abstract
We have developed a "sandwich"-type immunoradiometric assay for corticotropin (ACTH), with a detection limit of 2 ng/L. Two antibodies are used: a mouse monoclonal antibody directed against ACTH[1-17] and labeled with 125I; and a purified polyclonal goat antibody directed against ACTH[34-39] and conjugated to biotin. We could separate 125I-labeled antibody bound to ACTH from 125I-labeled antibody not bound to ACTH by using an avidin-biotin bridge, with avidin bound to a polystyrene ball. This assay reacts with ACTH[1-39] but shows no reaction with ACTH fragments [1-24], [1-17], or [34-39], or with melanotropin, endorphins, or lipotropin. This assay is sensitive enough to detect ACTH in plasma of all normal adults. Concentrations measured in 94 adults between 0800 and 1000 hours were normally distributed on a log scale, with a mean of 19.5 ng/L and a 95% range of 7.1 to 53.8 ng/L. Dexamethasone given at 2300 hours to 14 adults suppressed ACTH to less than 4 ng/L in 13 of the subjects and to 8 ng/L in the 14th. Metyrapone given to 13 adults at 2300 hours increased ACTH to 245.3 ng/L (95% range, 90.1 to 667.7 ng/L). This assay accurately classified patients with disorders of the adrenal system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sudo, N., Chida, Y., Aiba, Y., Sonoda, J., Oyama, N., Yu, X., Kubo, C., & Koga, Y. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.063388 · Cited by 2,735
The biotin-(strept)avidin system: principles and applications in biotechnology
Diamandis, E. P., & Christopoulos, T. K. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.5.625 · Cited by 747
Lupien, S. J., Gillin, C. J., & Hauger, R. L. (1999) · Behavioral Neuroscience · doi:10.1037/0735-7044.113.3.420 · Cited by 561
A Decade of Development in Immunoassay Methodology
Gosling, J. P. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.8.1408 · Cited by 457
Kanitz, E., Tuchscherer, M., Puppe, B., Tuchscherer, A., & Stabenow, B. (2004) · Brain, Behavior, and Immunity · doi:10.1016/s0889-1591(03)00085-0 · Cited by 200
Metadata
- Authors
- Zahradnik, R., Brennan, G., Hutchison, J. S., & Odell, W. D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-05-01
- Volume
- 35
- Issue
- 5
- Pages
- 804-807
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4299367238
- Cited by
- 60
- References
- 0
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immunoradiometric assay of corticotropin with use of avidin-biotin separation. https://app.cochat.ai/papers/10.1093/clinchem/35.5.804
- The paper
- Zahradnik, R., Brennan, G., Hutchison, J. S., & Odell, W. D. (1989). Immunoradiometric assay of corticotropin with use of avidin-biotin separation. Clinical Chemistry. https://doi.org/10.1093/clinchem/35.5.804
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.