The DOI matches its Crossref record.
Fully automated fluorescence assay for determining total homocysteine in plasma.
Abstract
Homocysteine exists in human plasma as various (mixed) disulfides. Most plasma homocysteine (about 70%) is protein bound, probably via a disulfide bond to albumin, whereas homocysteine-cysteine mixed disulfide is the predominating form in the free fraction. We here present a method for the determination of total homocysteine, which includes both fractions. Plasma was initially treated with sodium borohydride to reduce the disulfide bonds, and the liberated thiols were derivatized with monobromobimane. The derivatized sample, still containing the plasma proteins, was injected onto a strong cation-exchange column, from which the homocysteine derivative was directed by column switching into a cyclohexyl silica (CH) column. The homocysteine derivative was top-concentrated on the CH column, then rapidly eluted with a steep gradient of methanol. Both the derivatization procedure and chromatography were performed with a combined sample processor and sample injector from Gilson (Model 232-401). Within-run and between-run precision (CV) was less than 4%, and the detection limit of 0.2 pmol was sufficiently low for monitoring homocysteine in plasma. We verified the assay against two established manual methods for the determination of total homocysteine in plasma. This, the first fully automated assay for total plasma homocysteine, allows the unattended analysis of 70 samples per 24 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Facts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Self-citationRapid high-performance liquid chromatographic assay for total homocysteine levels in human serum
Ubbink, J. B., Hayward Vermaak, W. J., & Bissbort, S. (1991) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(91)80407-4 · Cited by 678
Jacobsen, D. W., Gatautis, V. J., Green, R., Robinson, K., Savon, S. R., Secic, M., Ji, J., Otto, J. M., & Taylor, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.6.873 · Cited by 435
Schneede, J., Dagnelie, P. C., Van Staveren, W. A., Vollset, S. E., Refsum, H., & Ueland, P. M. (1994) · Pediatric Research · doi:10.1203/00006450-199408000-00010 · Cited by 101
Self-citationDoets, E. L., Ueland, P. M., Tell, G. S., Vollset, S. E., Nygård, O. K., van't Veer, P., de Groot, L. C. P. G. M., Nurk, E., Refsum, H., Smith, A. D., et al. (2014) · British Journal Of Nutrition · doi:10.1017/s000711451300336x · Cited by 50
Metadata
- Authors
- Refsum, H., Ueland, P. M., & Svardal, A. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-09-01
- Volume
- 35
- Issue
- 9
- Pages
- 1921-1927
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1943195050
- Cited by
- 196
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully automated fluorescence assay for determining total homocysteine in plasma. https://app.cochat.ai/papers/10.1093/clinchem/35.9.1921
- The paper
- Refsum, H., Ueland, P. M., & Svardal, A. M. (1989). Fully automated fluorescence assay for determining total homocysteine in plasma. Clinical Chemistry. https://doi.org/10.1093/clinchem/35.9.1921
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.