Setting analytical goals for random analytical error in specific clinical monitoring situations
The DOI matches its Crossref record.
Abstract
Strategies abound for the setting of analytical goals in clinical chemistry. Many, especially those more recently proposed for particular clinical situations, are concerned with tests used in diagnosis. We suggest a general theory for the setting of goals in situations that specifically involve the monitoring of individuals. Goals are calculated from the formula CVA less than [(delta c 2/2Z2)-CVB2]1/2, where CVA is the analytical imprecision (as coefficient of variation, CV); delta c is the percentage change in serial results that is considered clinically significant; Z is the Z-statistic, which depends only on the probability selected for statistical significance; and CVB is the average inherent within-subject biological variation (as CV). Examples given show applications in hematology and in monitoring diabetes mellitus, chronic renal failure, and hepatitis. The derived goals are for total random analytical error (imprecision and intermittent systematic variation), and provide objective criteria that should be achieved in practice. The effect of analytical variability on both variability in test results and the probability that a stated change can be considered significant should be calculated whether or not the goals are attained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Self-citationBiological variation and diagnostic accuracy of dehydration assessment markers
Cheuvront, S. N., Ely, B. R., Kenefick, R. W., & Sawka, M. N. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.29490 · Cited by 367
Establishing Reference Intervals for Clinical Laboratory Test Results: Is There a Better Way?
Katayev, A., Balciza, C., & Seccombe, D. W. (2010) · American Journal of Clinical Pathology · doi:10.1309/ajcpn5bmtsf1cdyp · Cited by 280
Homeostatic control of the thyroid-pituitary axis: perspectives for diagnosis and treatment
Hoermann, R., Midgley, J. E. M., Larisch, R., & Dietrich, J. W. (2015) · Frontiers in Endocrinology · doi:10.3389/fendo.2015.00177 · Cited by 143
Metadata
- Authors
- Fraser, C. G., Hyltoft Peterson, P., & Larsen, M. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-09-01
- Volume
- 36
- Issue
- 9
- Pages
- 1625-1628
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1860041361
- Cited by
- 104
- References
- 0
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Setting analytical goals for random analytical error in specific clinical monitoring situations. https://app.cochat.ai/papers/10.1093/clinchem/36.9.1625
- The paper
- Fraser, C. G., Hyltoft Peterson, P., & Larsen, M. L. (1990). Setting analytical goals for random analytical error in specific clinical monitoring situations. Clinical Chemistry. https://doi.org/10.1093/clinchem/36.9.1625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.