The DOI matches its Crossref record.
International Federation of Clinical Chemistry standardization project for measurements of apolipoproteins A-I and B
Abstract
To minimize differences in apolipoprotein measurements among laboratories and methods, a standardization program involving common suitable reference material is needed. The Committee on Apolipoproteins of the International Federation of Clinical Chemistry initiated a collaborative study for the standardization of test systems for measuring apolipoproteins (apo) A-I and B, with 25 company laboratories and three research laboratories involved in apolipoprotein analysis to: (a) evaluate calibration differences among the test systems; (b) evaluate whether comparability of the data can be achieved with the use of frozen serum pools to recalibrate the different systems; and (c) evaluate and select suitable candidate reference material. We used 26 test systems for apo A-I and 28 for apo B. Relatively modest differences were found in calibration for apo A-I, but very wide differences were observed for apo B methods. After uniform calibration, the overall among-laboratory CV for apo B decreased from 19% to 6%. Three lyophilized serum preparations for apo A-I and three liquid-stabilized serum preparations for apo B were selected for further evaluation as candidate international reference materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cnop, M., Havel, P. J., Utzschneider, K. M., Carr, D. B., Sinha, M. K., Boyko, E. J., Retzlaff, B. M., Knopp, R. H., Brunzell, J. D., & Kahn, S. E. (2003) · Diabetologia · doi:10.1007/s00125-003-1074-z · Cited by 1,483
Lipoprotein Management in Patients With Cardiometabolic Risk
Brunzell, J. D., Davidson, M., Furberg, C. D., Goldberg, R. B., Howard, B. V., Stein, J. H., & Witztum, J. L. (2008) · Diabetes Care · doi:10.2337/dc08-9018 · Cited by 707
Nawrocki, J. W., Weiss, S. R., Davidson, M. H., Sprecher, D. L., Schwartz, S. L., Lupien, P.-J., Jones, P. H., Haber, H. E., & Black, D. M. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.15.5.678 · Cited by 484
Contois, J. H., McConnell, J. P., Sethi, A. A., Csako, G., Devaraj, S., Hoefner, D. M., & Warnick, G. R. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.118356 · Cited by 326
Marcovina, S. M., Albers, J. J., Scanu, A. M., Kennedy, H., Giaculli, F., Berg, K., Couderc, R., Dati, F., Rifai, N., Sakurabayashi, I., et al. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.12.1956 · Cited by 313
Self-citation
Metadata
- Authors
- Marcovina, S. M., Albers, J. J., Dati, F., Ledue, T. B., & Ritchie, R. F.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-10-01
- Volume
- 37
- Issue
- 10
- Pages
- 1676-1682
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2207843920
- Cited by
- 228
- References
- 0
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: International Federation of Clinical Chemistry standardization project for measurements of apolipoproteins A-I and B. https://app.cochat.ai/papers/10.1093/clinchem/37.10.1676
- The paper
- Marcovina, S. M., Albers, J. J., Dati, F., Ledue, T. B., & Ritchie, R. F. (1991). International Federation of Clinical Chemistry standardization project for measurements of apolipoproteins A-I and B. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.10.1676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.