Determination of silver in blood, urine, and tissues of volunteers and burn patients
Abstract
Silver sulfadiazine cream (SSD) has been used successfully in the management of burn wound sepsis. Silver deposition has been found in the skin, gingiva, cornea, liver, and kidney of patients treated with this cream, causing argyria, ocular injury, leukopenia, and toxicity in kidney, liver, and neurologic tissues. Monitoring concentrations of silver in blood and urine of patients receiving this treatment has become necessary, but sensitive and suitable methods adaptable to a clinical laboratory are still needed. We have developed a flameless thermal atomic absorption spectrophotometric method to measure silver concentrations in blood, urine, and other tissues. The detection limit is 0.4 microgram/L; the within-run precisions (CV) are 5.16%, 3.83%, and 2.79% for concentrations of 5, 13.5, and 42 micrograms/L, respectively; and the between-run precisions are 4.3% and 3.2% for concentrations of 13.5 and 42 micrograms/L. The concentrations of silver in blood, urine, liver, and kidney of subjects without industrial or medicinal exposure are less than 2.3 micrograms/L, 2 micrograms/day, 0.05 microgram/g wet tissue, and 0.05 microgram/g wet tissue, respectively. In SSD cream-treated burn patients, plasma concentrations may be as great as 50 micrograms/L within 6 h of treatment and can reach a maximum of 310 micrograms/L. Silver in urine is detectable after one day of treatment and may reach a maximum of 400 micrograms/day. After absorption, silver was found to be deposited in various tissues. Tissue silver concentrations in one burn patient who died of renal failure after eight days of treatment were 970, 14, and 0.2 micrograms/g wet tissue in cornea, liver, and kidney, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Electrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
Gupta, V. K., Ganjali, M. R., Norouzi, P., Khani, H., Nayak, A., & Agarwal, S. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.589773 · Cited by 580
Gosheger, G., Hardes, J., Ahrens, H., Streitburger, A., Buerger, H., Erren, M., Gunsel, A., Kemper, F. H., Winkelmann, W., & von Eiff, C. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.008 · Cited by 441
Hadrup, N., Sharma, A. K., & Loeschner, K. (2018) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2018.08.007 · Cited by 348
Metadata
- Authors
- Wan, A. T., Conyers, R. A., Coombs, C. J., & Masterton, J. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-10-01
- Volume
- 37
- Issue
- 10
- Pages
- 1683-1687
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1947292443
- Cited by
- 242
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of silver in blood, urine, and tissues of volunteers and burn patients. https://app.cochat.ai/papers/10.1093/clinchem/37.10.1683
- The paper
- Wan, A. T., Conyers, R. A., Coombs, C. J., & Masterton, J. P. (1991). Determination of silver in blood, urine, and tissues of volunteers and burn patients. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.10.1683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.