Plasma renin activity and plasma prorenin assays
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Sensitivity and accuracy are essential features of an assay of plasma renin activity (PRA) because the normal concentration of PRA is only 1 pmol/L, and subnormal concentrations have diagnostic relevance. Conditions for blood collection need to be standardized but the conditions are not difficult for outpatients. For routine diagnostic purposes blood should be collected from ambulatory (ideally, untreated) patients on moderate sodium intake. To avoid irreversible cryoactivation of plasma prorenin (which is present in 10-fold greater concentrations than renin), samples should be processed at room temperature and stored completely frozen. Cryoactivation occurs when plasma is liquid at temperatures less than 6 degrees C. PRA is commonly measured with an enzyme kinetic assay in which angiotensin I (Ang I) is formed by the reaction of plasma renin with endogenous renin substrate (angiotensinogen). The Ang I so formed is measured by RIA; results are expressed as an hourly rate (micrograms/L formed per hour). This method, which is provided by most commercial kits, has the potential for unlimited sensitivity because the step for Ang I generation can be prolonged as long as necessary, so that enough Ang I forms to be measured accurately. Unfortunately, that sensitivity is not always exploited. Dilution of plasma during pH adjustment should be kept to a minimum. The Ang I generation step should last at least 3 h. The step should last 18 h for samples with PRA less than 1.0 micrograms/L per hour, to eliminate the errors inherent in the measurement and subtraction of immunoreactive Ang I in the untreated plasma (blank subtraction). These changes actually simplify PRA measurements because they eliminate the need for ice in the clinic and reduce by almost half the number of samples to be assayed by RIA. I also describe the method for measurement of plasma prorenin, which may be an important marker for patients with diabetes mellitus who subsequently develop vascular complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HABER, E., KOERNER, T., PAGE, L. B., KLIMAN, B., & PURNODE, A. (1969) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-29-10-1349 · Cited by 2,222 · cited 1×
“However, the commonly referenced method of Haber’s group did not advocate pH control (9).”
MethodThe renin system: Variations in man measured by radioimmunoassay or bioassay
Sealey, J. E., Gerten-Banes, J., & Laragh, J. H. (1972) · Kidney International · doi:10.1038/ki.1972.34 · Cited by 382 · cited 1×
“Plasma renin substrate is ordinarily measured by radioimmunoassay of the amount of angiotensin I formed after incubating a small amount of plasma with excess human renin in the presence of angiotensinase and converting enzyme inhibitors (19).”
MethodSelf-citationProrenin and Other Large Molecular Weight Forms of Renin*
SEALEY, J. E., ATLAS, S. A., & LARAGH, J. H. (1980) · Endocrine Reviews · doi:10.1210/edrv-1-4-365 · Cited by 232 · cited 2×
“This error, which causes falsely high values, cannot be eliminated by a correction factor because cryoactivated prorenin is indistinguishable from renin, and because renin and prorenin do not occur in plasma in a fixed ratio; certain factors that affect the concentrations of plasma renin may have the opposite effect o…”
BackgroundSelf-citationRadioimmunoassay of plasma renin activity
Sealey, J. E., & Laragh, J. H. (1975) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(75)80033-x · Cited by 172
Self-citationPlasma prorenin activity and complications in children with insulin-dependent diabetes mellitus.
Wilson, D. M., & Luetscher, J. (1990) · New England Journal of Medicine · doi:10.1056/nejm199010183231604 · Cited by 154 · cited 2×
“Because plasma prorenin has recently been proposed as a marker for patients with diabetes mellitus who go on to develop retinopathy and nephropathy (4), I also describe this method in some detail, but touch only briefly upon measurement of other components of the system, renin substrate (angiotensinogen) and angiotens…”
BackgroundHigh blood pressure and oral contraceptives
Newton, M. A., Sealey, J. E., Ledingham, J. G. G., & Laragh, J. H. (1968) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(68)90345-1 · Cited by 120 · cited 1×
“Menten equation and a Km of 2700 1zg/L (17):”
BackgroundSelf-citation
Cited by
de Simone, G., Devereux, R. B., Roman, M. J., Ganau, A., Saba, P. S., Alderman, M. H., & Laragh, J. H. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90390-5 · Cited by 607
Carson, P., Ziesche, S., Johnson, G., & Cohn, J. N. (1999) · Journal of Cardiac Failure · doi:10.1016/s1071-9164(99)90001-5 · Cited by 533
Candidate‐based proteomics in the search for biomarkers of cardiovascular disease
Anderson, L. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2004.080473 · Cited by 378
Alderman, M. H., Madhavan, S., Cohen, H., Sealey, J. E., & Laragh, J. H. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1144 · Cited by 299
Self-citationBanfi, G., Salvagno, G. L., & Lippi, G. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.110 · Cited by 297
Schwartz, G. L., & Turner, S. T. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.041780 · Cited by 221
Sex differences in cardiovascular function during submaximal exercise in humans
Wheatley, C. M., Snyder, E. M., Johnson, B. D., & Olson, T. P. (2014) · SpringerPlus · doi:10.1186/2193-1801-3-445 · Cited by 179
“Clin Auton Res 20(4):271–275, doi:10.1007/s10286-010-0061-y Sealey JE (1991) Plasma renin activity and plasma prorenin assays.”
MethodInfluentialSealey, J. E., Itskovitz-Eldor, J., Rubattu, S., James, G. D., August, P., Thaler, I., Levron, J., & Laragh, J. H. (1994) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.79.1.8027239 · Cited by 115
Self-citationBertholf, R. L., Jialal, I., & Winter, W. E. (2012) · Tietz Textbook of Clinical Chemistry and Molecular Diagnostics · doi:10.1016/b978-1-4160-6164-9.00054-8 · Cited by 5
Metadata
- Authors
- Sealey, J. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-10-01
- Volume
- 37
- Issue
- 10
- Pages
- 1811-1819
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1827617621
- Cited by
- 207
- References
- 6
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.