Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 558

The DOI matches its Crossref record.

Electrochemiluminescence detection for development of immunoassays and DNA probe assays for clinical diagnostics

Blackburn, G F, Shah, H P, Kenten, J H, Leland, J, Kamin, R A, Link, J, Peterman, J, Powell, M J, Shah, A, Talley, D B·1991·Clinical Chemistry

Abstract

Electrochemiluminescence (ECL) has been developed as a highly sensitive process in which reactive species are generated from stable precursors (i.e., the ECL-active label) at the surface of an electrode. This new technology has many distinct advantages over other detection systems: no radioisotopes are used; detection limits for label are extremely low (200 fmol/L); the dynamic range for label quantification extends over six orders of magnitude; the labels are extremely stable compared with those of most other chemiluminescent systems; the labels, small molecules (approximately 1000 Da), can be used to label haptens or large molecules, and multiple labels can be coupled to proteins or oligonucleotides without affecting immunoreactivity, solubility, or ability to hybridize; because the chemiluminescence is initiated electrochemically, selectivity of bound and unbound fractions can be based on the ability of labeled species to access the electrode surface, so that both separation and nonseparation assays can be set up; and measurement is simple and rapid, requiring only a few seconds. We illustrate ECL in nonseparation immunoassays for digoxin and thyrotropin and in separation immunoassays for carcinoembryonic antigen and alpha-fetoprotein. The application of ECL for detection of polymerase chain reaction products is described and exemplified by quantifying the HIV1 gag gene.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/37.9.1534

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 558

Metadata

Authors
Blackburn, G. F., Shah, H. P., Kenten, J. H., Leland, J., Kamin, R. A., Link, J., Peterman, J., Powell, M. J., Shah, A., & Talley, D. B.
Venue
Clinical Chemistry
Published
1991-09-01
Volume
37
Issue
9
Pages
1534-1539
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2117152469
Cited by
558
References
0
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemiluminescence detection for development of immunoassays and DNA probe assays for clinical diagnostics. https://app.cochat.ai/papers/10.1093/clinchem/37.9.1534
The paper
Blackburn, G. F., Shah, H. P., Kenten, J. H., Leland, J., Kamin, R. A., Link, J., Peterman, J., Powell, M. J., Shah, A., & Talley, D. B. (1991). Electrochemiluminescence detection for development of immunoassays and DNA probe assays for clinical diagnostics. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.9.1534

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.