Charts of operational process specifications ("OPSpecs charts") for assessing the precision, accuracy, and quality control needed to satisfy proficiency testing performance criteria
The DOI matches its Crossref record.
Abstract
“Operational process specifications” have been derived from an analytical quality-planning model to assess the precision, accuracy, and quality control (QC) needed to satisfy Proficiency Testing (PT) criteria. These routine operating specifications are presented in the form of an “OPSpecs chart,” which describes the operational limits for imprecision and inaccuracy when a desired level of quality assurance is provided by a specific QC procedure. OPSpecs charts can be used to compare the operational limits for different QC procedures and to select a QC procedure that is appropriate for the precision and accuracy of a specific measurement procedure. To select a QC procedure, one plots the inaccuracy and imprecision observed for a measurement procedure on the OPSpecs chart to define the current operating point, which is then compared with the operational limits of candidate QC procedures. Any QC procedure whose operational limits are greater than the measurement procedure's operating point will provide a known assurance, with the percent chance specified by the OPSpecs chart, that critical analytical errors will be detected. OPSpecs charts for a 10% PT criterion are presented to illustrate the selection of QC procedures for measurement procedures with different amounts of imprecision and inaccuracy. Normalized OPSpecs charts are presented to permit a more general assessment of the analytical performance required with commonly used QC procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Boyd, J. C., & Bruns, D. E. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.209 · Cited by 227
Amukele, T. K., Sokoll, L. J., Pepper, D., Howard, D. P., & Street, J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134020 · Cited by 139
Useful measures and models for analytical quality management in medical laboratories
Westgard, J. O. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0710 · Cited by 64
Self-citationChhapola, V., Kanwal, S. K., Sharma, R., & Kumar, V. (2013) · The Indian Journal of Pediatrics · doi:10.1007/s12098-013-0977-z · Cited by 33
Metadata
- Authors
- Westgard, J. O.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-07-01
- Volume
- 38
- Issue
- 7
- Pages
- 1226-1233
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1901499625
- Cited by
- 85
- References
- 0
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Charts of operational process specifications ("OPSpecs charts") for assessing the precision, accuracy, and quality control needed to satisfy proficiency testing performance criteria. https://app.cochat.ai/papers/10.1093/clinchem/38.7.1226
- The paper
- Westgard, J. O. (1992). Charts of operational process specifications ("OPSpecs charts") for assessing the precision, accuracy, and quality control needed to satisfy proficiency testing performance criteria. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.7.1226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.