Progress Toward the Development of an Implantable Sensor for Glucose
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The development of an electrochemically based implantable sensor for glucose is described. The sensor is needle-shaped, about the size of a 28-gauge needle. It is flexible and must be implanted subcutaneously by using a 21-gauge catheter, which is then removed. When combined with a monitoring unit, this device, based on the glucose oxidase-catalyzed oxidation of glucose, reliably monitors glucose concentrations for as long as 10 days in rats. Various design considerations, including the decision to monitor the hydrogen peroxide produced in the enzymatic reaction, are discussed. Glucose constitutes the most important future target analyte for continuous monitoring, but the basic methodology developed for glucose could be applied to several other analytes such as lactate or ascorbate. The success in implementation of such a device depends on a reaction of the tissue surrounding the implant so as not to interfere with the proper functioning of the sensor. Histochemical evidence indicates that the tissue response leads to enhanced sensor performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Zhang, Y., & Wilson, G. S. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)85009-9 · Cited by 92
Self-citationApplication of cell culture toxicity tests to the development of implantable biosensors
Zhang, Y., Bindra, D. S., Barrau, M.-B., & Wilson, G. S. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)87018-7 · Cited by 25
Self-citation
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Microbial fuel cell as new technology for bioelectricity generation: A review
Rahimnejad, M., Adhami, A., Darvari, S., Zirepour, A., & Oh, S.-E. (2015) · Alexandria Engineering Journal · doi:10.1016/j.aej.2015.03.031 · Cited by 781
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Metadata
- Authors
- Wilson, G. S., Zhang, Y., Reach, G., Moatti-Sirat, D., Poitout, V, Thévenot, D. R., Lemonnier, F., & Klein, J. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 38
- Issue
- 9
- Pages
- 1613-1617
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4299649886
- Cited by
- 98
- References
- 3
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progress Toward the Development of an Implantable Sensor for Glucose. https://app.cochat.ai/papers/10.1093/clinchem/38.9.1613
- The paper
- Wilson, G. S., Zhang, Y., Reach, G., Moatti-Sirat, D., Poitout, V, Thévenot, D. R., Lemonnier, F., & Klein, J. C. (1992). Progress Toward the Development of an Implantable Sensor for Glucose. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.9.1613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.