The DOI matches its Crossref record.
Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation
Abstract
Noninvasive monitoring of blood/tissue glucose concentrations has been successfully accomplished in individual diabetic subjects by using near-infrared (NIR) spectroscopy coupled with chemometric methods. Three different spectrometer configurations were tested: a) a Fourier-transform infrared spectrometer with an indium antimonide detector; b) a grating monochromator equipped with a silicon (Si) array detector, without fiber optics; and c) a grating monochromator equipped with an Si detector, with fiber-optic sampling. NIR spectra were obtained from diabetic subjects by transmission through the finger during a meal-tolerance test. The maximum range of observed plasma glucose concentrations obtained from the blood samples was 2.5-27 mmol/L. The NIR spectra were processed by using the chemometric multivariate calibration methods of partial least squares and principal component regression. The best calibration yielded a cross-validated average absolute error in glucose concentration of 1.1 mmol/L. This predictive ability suggests that noninvasive glucose determinations by NIR/chemometrics is a viable analytical method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200
Metadata
- Authors
- Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 38
- Issue
- 9
- Pages
- 1618-1622
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2149482687
- Cited by
- 284
- References
- 0
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation. https://app.cochat.ai/papers/10.1093/clinchem/38.9.1618
- The paper
- Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L. (1992). Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.9.1618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.