The DOI matches its Crossref record.
Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared
Open accessAbstract
Tissue glucose levels affect the refractive index of the extracellular fluid. The difference in refractive index between the extracellular fluid and the cellular components plays a role in determining the reduced scattering coefficient (micro(s)') of tissue. Hence a physical correlation may exist between the reduced scattering coefficient and glucose concentration. We have designed and constructed a frequency-domain near-infrared tissue spectrometer capable of measuring the reduced scattering coefficient of tissue with enough precision to detect changes in glucose levels in the physiological and pathological range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Oxygen Saturation-Dependent Absorption and Scattering of Blood
Faber, D. J., Aalders, M. C. G., Mik, E. G., Hooper, B. A., van Gemert, M. J. C., & van Leeuwen, T. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.028102 · Cited by 264
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Self-citation
Metadata
- Authors
- Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1994-12-15
- Volume
- 19
- Issue
- 24
- Pages
- 2062
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1998548833
- Cited by
- 318
- References
- 0
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared. https://app.cochat.ai/papers/10.1364/ol.19.002062
- The paper
- Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994). Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared. Optics Letters. https://doi.org/10.1364/ol.19.002062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.