The DOI matches its Crossref record.
Homocysteine and other thiols in plasma and urine: automated determination and sample stability
Abstract
We have developed a modified version of our fully automated column-switching HPLC method for determining total plasma homocysteine based on single-column (reversed-phase) separation. Homocysteine, cysteine, and cysteinylglycine in plasma (total concentrations), acid-precipitated plasma (non-protein-bound concentrations), and urine can be determined. The derivatization and chromatography were performed automatically by a sample processor. The successful separation of all thiol species (within 15 min) was accomplished by accurate adjustment of the pH of the mobile phase to 3.65 (plasma) or 3.50 (acid-precipitated plasma, urine). Maximal fluorescence yield of cysteine, cysteinylglycine, and, to a lesser degree, homocysteine was dependent on optimal concentrations of EDTA and dithioerythritol during reduction (with NaBH4) and derivatization (with monobromobimane). The method is sensitive (detection limit approximately 0.05 pmol) and has a high degree of precision (CV < 5%). The sample output is approximately 70 samples in 24 h. Serum and heparin plasma can also be analyzed. Hemolysis up to approximately 2.0 g/L of hemoglobin did not interfere with the analytical recovery of homocysteine or cysteine. Collection of blood, separation of plasma from whole blood, and acid precipitation must be standardized to obtain reproducible thiol results. Our modifications and the standardization of blood-sampling procedures have substantially improved the method and broadened its applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Self-citationFacts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Self-citationJacobsen, D. W., Gatautis, V. J., Green, R., Robinson, K., Savon, S. R., Secic, M., Ji, J., Otto, J. M., & Taylor, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.6.873 · Cited by 435
Current issues in measurement and reporting of urinary albumin excretion
Miller, W. G., Bruns, D. E., Hortin, G. L., Sandberg, S., Aakre, K. M., McQueen, M. J., Itoh, Y., Lieske, J. C., Seccombe, D. W., Jones, G., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106567 · Cited by 381
Klee, G. G. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.8.1277 · Cited by 384
Metadata
- Authors
- Fiskerstrand, T., Refsum, H., Kvalheim, G., & Ueland, P. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-02-01
- Volume
- 39
- Issue
- 2
- Pages
- 263-271
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1954829482
- Cited by
- 469
- References
- 0
- FWCI
- 17.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Homocysteine and other thiols in plasma and urine: automated determination and sample stability. https://app.cochat.ai/papers/10.1093/clinchem/39.2.263
- The paper
- Fiskerstrand, T., Refsum, H., Kvalheim, G., & Ueland, P. M. (1993). Homocysteine and other thiols in plasma and urine: automated determination and sample stability. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.2.263
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.