Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 469

The DOI matches its Crossref record.

Homocysteine and other thiols in plasma and urine: automated determination and sample stability

Fiskerstrand, T, Refsum, H, Kvalheim, G, Ueland, P M·1993·Clinical Chemistry

Abstract

We have developed a modified version of our fully automated column-switching HPLC method for determining total plasma homocysteine based on single-column (reversed-phase) separation. Homocysteine, cysteine, and cysteinylglycine in plasma (total concentrations), acid-precipitated plasma (non-protein-bound concentrations), and urine can be determined. The derivatization and chromatography were performed automatically by a sample processor. The successful separation of all thiol species (within 15 min) was accomplished by accurate adjustment of the pH of the mobile phase to 3.65 (plasma) or 3.50 (acid-precipitated plasma, urine). Maximal fluorescence yield of cysteine, cysteinylglycine, and, to a lesser degree, homocysteine was dependent on optimal concentrations of EDTA and dithioerythritol during reduction (with NaBH4) and derivatization (with monobromobimane). The method is sensitive (detection limit approximately 0.05 pmol) and has a high degree of precision (CV < 5%). The sample output is approximately 70 samples in 24 h. Serum and heparin plasma can also be analyzed. Hemolysis up to approximately 2.0 g/L of hemoglobin did not interfere with the analytical recovery of homocysteine or cysteine. Collection of blood, separation of plasma from whole blood, and acid precipitation must be standardized to obtain reproducible thiol results. Our modifications and the standardization of blood-sampling procedures have substantially improved the method and broadened its applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/39.2.263

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 469

Metadata

Authors
Fiskerstrand, T., Refsum, H., Kvalheim, G., & Ueland, P. M.
Venue
Clinical Chemistry
Published
1993-02-01
Volume
39
Issue
2
Pages
263-271
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1954829482
Cited by
469
References
0
FWCI
17.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Homocysteine and other thiols in plasma and urine: automated determination and sample stability. https://app.cochat.ai/papers/10.1093/clinchem/39.2.263
The paper
Fiskerstrand, T., Refsum, H., Kvalheim, G., & Ueland, P. M. (1993). Homocysteine and other thiols in plasma and urine: automated determination and sample stability. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.2.263

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.