The DOI matches its Crossref record.
Lipase in serum--the elusive enzyme: an overview
Abstract
Lipase is a glycoprotein with 420-449 amino acid residues and a M(r) of 46,000-56,000 for pancreatic lipase and 32,000-39,000 for serum lipase. Lipase is present in the pancreas, intestines, and a variety of other tissues. The concentration gradient between pancreatic tissue and serum lipase is approximately 20,000-fold. Serine, as part of an Asp-His-Ser triad, is the nucleophilic residue essential for catalysis. Lipase differs from other esterases by the presence of a hydrophobic recognition site. The optimal pH is between 7.5 and 10.0, depending on the reaction condition; the pI for the various forms of the enzyme has been reported as 5.80 and 5.85; 6.4, 6.8, and 7.0; and 7.4 for a purified fraction. Several authors report the presence of two molecular forms in the pancreas and three electrophoretic bands with lipolytic activity. In normal serum two bands have been observed; in pancreatitis as many as four bands have been seen. Lipolytic activity may not always be due to lipase. Assays specific for lipase require a triglyceride as substrate as well as the presence of colipase (a water-soluble and heat-stable protein, essential for lipase action), a secondary bile salt, and Ca2+. The clinical sensitivity of all modern assays is high because of selection of a low decision limit; the clinical specificity varies greatly but can be improved by increasing the cutoff point. Lipase determinations in pancreatitis are superior to amylase determinations. The reasons for the great variability of reports regarding the clinical utility of lipase are discussed, and the clinical utility of lipase determinations is summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PCL and PCL-based materials in biomedical applications
Malikmammadov, E., Tanir, T. E., Kiziltay, A., Hasirci, V., & Hasirci, N. (2018) · Journal of Biomaterials Science, Polymer Edition · doi:10.1080/09205063.2017.1394711 · Cited by 894
Microbial lipases and their industrial applications: a comprehensive review
Chandra, P., Enespa, Singh, R., & Arora, P. K. (2020) · Microbial Cell Factories · doi:10.1186/s12934-020-01428-8 · Cited by 887
A critical evaluation of laboratory tests in acute pancreatitis
Yadav, D. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04122-9 · Cited by 375
Electrospun Polycaprolactone (PCL) Degradation: An In Vitro and In Vivo Study
Dias, J. R., Sousa, A., Augusto, A., Bártolo, P. J., & Granja, P. L. (2022) · Polymers · doi:10.3390/polym14163397 · Cited by 293
Nair, S. (2000) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(00)01981-x · Cited by 290
Metadata
- Authors
- Tietz, N. W., & Shuey, D. F.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-05-01
- Volume
- 39
- Issue
- 5
- Pages
- 746-756
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2120910672
- Cited by
- 181
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lipase in serum--the elusive enzyme: an overview. https://app.cochat.ai/papers/10.1093/clinchem/39.5.746
- The paper
- Tietz, N. W., & Shuey, D. F. (1993). Lipase in serum--the elusive enzyme: an overview. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.5.746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.