Desirable standards for laboratory tests if they are to fulfill medical needs
The DOI matches its Crossref record.
Abstract
Many strategies to define desirable standards for laboratory tests to fulfill medical needs have been proposed over the last three decades. Traditional approaches are based on reference (normal) values, opinions of clinicians, the state of the art, views of experts, data on biological variation, and assessment of the effect of error on clinical use. All these approaches have advantages and disadvantages, but the consensus of experts reached over a decade ago that imprecision desirably be less than one-half of the within-subject biological variation still seems to provide the best set of generally applicable performance standards. Desirable bias is less than one-quarter of the group (within-subject plus between-subject) biological variation. Recent proposals are either restatements of traditional recommendations, further empirical suggestions, or models based on assessment of clinical needs, and have not been widely accepted. Both old and new studies on clinical opinions, sought by using structured questionnaires containing clinical vignettes designed to seek views on the magnitude of significant change, are flawed in design, execution, and data analysis. Until clinicians are more aware of test-result variability and clinical chemists gain quantitative knowledge on the interpretation of test results, it will be difficult to set desirable standards that fulfill actual medical needs, except in a few well-defined screening situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Self-citationBone turnover markers in the management of postmenopausal osteoporosis
Brown, J. P., Albert, C., Nassar, B. A., Adachi, J. D., Cole, D., Davison, K. S., Dooley, K. C., Don-Wauchope, A., Douville, P., Hanley, D. A., et al. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.04.001 · Cited by 204
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Self-citationCurrent status and performance goals for serum thyrotropin (TSH) assays
Spencer, C. A., Takeuchi, M., & Kazarosyan, M. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.1.140 · Cited by 181
Introduction: Strategies to set global quality specifications in laboratory medicine
C. G. Fraser, A. K. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185184 · Cited by 172
Metadata
- Authors
- Fraser, C. G., & Petersen, P. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-07-01
- Volume
- 39
- Issue
- 7
- Pages
- 1447-1455
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1860068137
- Cited by
- 109
- References
- 0
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Desirable standards for laboratory tests if they are to fulfill medical needs. https://app.cochat.ai/papers/10.1093/clinchem/39.7.1447
- The paper
- Fraser, C. G., & Petersen, P. H. (1993). Desirable standards for laboratory tests if they are to fulfill medical needs. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.7.1447
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.