Cited by 39Clinical Laboratory Practices and Quality ControlHormonal and reproductive studiesSperm and Testicular Function

Within- and between-subject biological variations of follitropin, lutropin, testosterone, and sex-hormone-binding globulin in men

Valero-Politi, J, Fuentes-Arderiu, X·1993·Clinical Chemistry

Abstract

The within-subject and between-subject biological variation of the serum concentrations of follitropin, lutropin, sex-hormone-binding globulin, and testosterone; the ratio between the serum concentrations of testosterone and sex-hormone-binding globulin; and the concentration of testosterone in saliva have been studied in a group of 20 men during 12 months. The between-subject coefficients of variation (CVs) were 36.0% for follitropin, 37.0% for lutropin, 42.7% for sex-hormone-binding globulin, 21.3% for testosterone in serum, 28.8% for testosterone in saliva, and 51.6% for the ratio between serum concentrations of testosterone and sex-hormone-binding globulin. The medians of the within-subject CVs for the respective analyses and ratio were 17.3%, 24.0%, 12.1%, 10.9%, 17.3%, and 9.4%. These data were used to calculate the desirable imprecision, the critical difference for significant change detection, and the index of individuality.

Integrity signals

Registry

Crossref · 10.1093/clinchem/39.8.1723

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Because of simplicity, ease of use, and high throughput, immunoassays were widely adopted in clinical practice, and most total testosterone reference ranges were established using them.

    “Given their simplicity, ease of use, and high-throughput, immunoassays (IA) were widely adopted in clinical practice, with the majority of TT reference ranges established using these techniques.”
  • Limitations of equilibrium dialysis include increased expense, dependence on total testosterone accuracy, and variations from radiotracer impurities, temperature control, and sample dilution.

    “Limitations with this technique include increased expense, dependence on TT accuracy, and variations created by radiotracer impurities, temperature control, and sample dilution, among others.”
  • Additional factors that may account for variability include specimen handling and preparation, calibration methods, specimen commutability, and interference from matrix material used to store and transport testosterone preparations.

    “Additional factors, which may account for variability of results include specimen handling and preparation, calibration methods utilized, specimen commutability, and interference from the matrix material used to store and transport sample T preparations.”

Cited by

Sorted by citations

Authors
Valero-Politi, J., & Fuentes-Arderiu, X.
Affiliations
Servei de Bioqímica Clínica, Hospital Prínceps d'Espanya, Barcelona
Venue
Clinical Chemistry
Published
1993-08-01
Volume
39
Issue
8
Pages
1723-1725
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1794650315
Cited by
39
References
0
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2019: 1 · 2018: 3 · 2016: 4 · 2015: 1 · 2014: 1 · 2013: 2
FWCI
0.22
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
  • Health Sciences › Medicine › Reproductive Medicine › Sperm and Testicular Function
Keywords
biological variation, within-person variability, interindividual variability, follicle-stimulating hormone, luteinizing hormone, testosterone, sex hormone-binding globulin, saliva testosterone, men, critical difference, index of individuality, imprecision
MeSH terms
Adult, Follicle Stimulating Hormone, Humans, Luteinizing Hormone, Male, Middle Aged, Reference Values, Saliva, Sex Hormone-Binding Globulin, Testosterone

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review