The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rate
Abstract
We describe a fully automated particle-enhanced turbidimetric assay for cystatin C in undiluted serum and EDTA-plasma. The throughput is 90 samples per hour and urgent samples can be analyzed in 7 min. The assay range (0.4-14.1 mg/L) covers the concentration range in health and disease. The within- and between-run imprecision is 0.9% and 2.2%, respectively. Analytical recovery of additions of recombinant cystatin C averaged 98%. Rheumatoid factors (< or = 323,000 IU/L), bilirubin (< or = 150 mumol/L), hemoglobin (< or = 1.2 g/L), and triglycerides (< or = 8.5 mmol/L) do not interfere in the assay. In view of the superior (by ROC analysis) diagnostic accuracy of serum concentrations of cystatin C for reduced glomerular filtration rate (GFR) in comparison with creatinine, cystatin C seems an attractive alternative to creatinine for estimation of GFR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The place of human γ-trace (cystatin C) amongst the cysteine proteinase inhibitors
Barrett, A. J., Davies, M. E., & Grubb, A. (1984) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(84)91302-0 · Cited by 294
Self-citation
Cited by
Cystatin C as a marker of GFR—history, indications, and future research
Filler, G., Bökenkamp, A., Hofmann, W., Le Bricon, T., Martínez-Brú, C., & Grubb, A. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.09.025 · Cited by 734
Self-citationRisch, L., Herklotz, R., Blumberg, A., & Huber, A. R. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.11.2055 · Cited by 343
Grubb, A., Horio, M., Hansson, L.-O., Björk, J., Nyman, U., Flodin, M., Larsson, A., Bökenkamp, A., Yasuda, Y., Blufpand, H., et al. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2013.220707 · Cited by 324
Self-citationBiochemistry and Clinical Role of Human Cystatin C
Mussap, M., & Plebani, M. (2004) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360490504934 · Cited by 313
Promoter-mediated, dexamethasone-induced increase in cystatin C production by HeLa cells
Bjarnadóttir, M., Grubb, A., & Ólafsson, Í. (1995) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519509110261 · Cited by 157
Self-citation
Metadata
- Authors
- Kyhse-Andersen, J., Schmidt, C., Nordin, G., Andersson, B., Nilsson-Ehle, P., Lindström, V, & Grubb, A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-10-01
- Volume
- 40
- Issue
- 10
- Pages
- 1921-1926
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2100510417
- Cited by
- 511
- References
- 1
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rate. https://app.cochat.ai/papers/10.1093/clinchem/40.10.1921
- The paper
- Kyhse-Andersen, J., Schmidt, C., Nordin, G., Andersson, B., Nilsson-Ehle, P., Lindström, V, & Grubb, A. (1994). Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric method, is a better marker than serum creatinine for glomerular filtration rate. Clinical Chemistry. https://doi.org/10.1093/clinchem/40.10.1921
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.