Cited by 309Clinical Laboratory Practices and Quality ControlHemodynamic Monitoring and TherapyTrauma, Hemostasis, Coagulopathy, Resuscitation

Composition of interstitial fluid

Fogh-Andersen, N, Altura, B M, Altura, B T, Siggaard-Andersen, O·1995·Clinical Chemistry

Abstract

In several previous experiments to determine the composition of interstitial fluid, the results varied depending on the collecting technique, and the electrolyte concentrations differed from those of a hypothetical ultrafiltrate of plasma. In our approach, since a change of position from standing to supine is accompanied by hemodilution with interstitial fluid, we used the changes in hematocrit and composition of plasma in 20 subjects before and after lying down to calculate the composition of added interstitial fluid. The estimated protein concentration was 20.6 g/L, and the concentrations of total calcium and magnesium were low, in accord with a lower concentration of protein-bound calcium and magnesium. The activity of free cations was also lower, in agreement with a Donnan equilibrium potential of 1 mV across the endothelium. The concentration of leukocytes and platelets decreased according to the hemodilution, implying no escape or mobilization of these elements.

Integrity signals

Registry

Crossref · 10.1093/clinchem/41.10.1522

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • ISF composition leads to reliable correlations between blood and ISF concentrations of many analytes, including electrolytes, metabolites, and proteins.

    “This function, and the associated ISF composition, lead to reliable correlations between the blood and ISF concentrations of many analytes, including electrolytes (e.g., sodium, phosphate, magnesium, potassium or calcium), metabolites (e.g., glucose, alcohol, lactate or cortisol) and proteins65-69.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [67]

The citation lists haven’t been fetched yet

References 12 · Cited by 309

Authors
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O.
Affiliations
  • Department of Clinical Chemistry, Herlev Hospital, Denmark
  • Herlev Hospital (DK)
Venue
Clinical Chemistry
Published
1995-10-01
Volume
41
Issue
10
Pages
1522-1525
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1937444536
Cited by
309
References
12
Citations by year
2026: 15 · 2025: 27 · 2024: 27 · 2023: 25 · 2022: 26 · 2021: 27 · 2020: 33 · 2019: 22 · 2018: 17 · 2017: 10 · 2016: 10 · 2015: 10 · 2014: 11 · 2013: 6 · 2012: 6
FWCI
0.22
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Trauma, Hemostasis, Coagulopathy, Resuscitation
Keywords
hemodilution, hematocrit, serum electrolytes, protein concentration, calcium, magnesium, protein-bound calcium, Donnan equilibrium, leukocytes, platelets, supine position
MeSH terms
Adult, Calcium, Cations, Erythrocyte Indices, Extracellular Space, Female, Hematocrit, Hemodilution, Humans, Hydrogen-Ion Concentration, Leukocyte Count, Magnesium, Male, Middle Aged, Phosphates, Platelet Count, Posture, Potassium, Proteins, Reference Values, Supine Position

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›