Nitrate determination in biological fluids by an enzymatic one-step assay with nitrate reductase

Bories, P N, Bories, C·1995·Clinical Chemistry

Abstract

We report a simple, enzymatic, end point method for determining nitrate in serum and urine with use of nitrate reductase from Aspergillus sp. (EC 1.6.6.2). The decrease in absorbance at 340 nm as a result of the oxidation of beta-NADPH is measured. We used FAD as a supplementary electron carrier and added an internal standard to avoid interference from possible inhibitors of the enzymatic reaction. The method was linear from 5 to 200 mumol/L nitrate in serum. Within-run (n = 12) and total (n = 14 days) imprecisions (CV) were 5.1-7.7% and 6.2-9.8%, respectively, at 20-90 mumol/L nitrate in serum. Recoveries of added nitrate were 80-106%. The median (range) concentration in serum of 20 healthy subjects was 16 (0-42) mumol/L.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/41.6.904

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 304

Metadata

Authors
Bories, P. N., & Bories, C.
Venue
Clinical Chemistry
Published
1995-06-01
Volume
41
Issue
6
Pages
904-907
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1851106608
Cited by
304
References
11
FWCI
5.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nitrate determination in biological fluids by an enzymatic one-step assay with nitrate reductase. https://app.cochat.ai/papers/10.1093/clinchem/41.6.904
The paper
Bories, P. N., & Bories, C. (1995). Nitrate determination in biological fluids by an enzymatic one-step assay with nitrate reductase. Clinical Chemistry. https://doi.org/10.1093/clinchem/41.6.904

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.