The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Candidate reference methods for hemoglobin A1c based on peptide mapping
Abstract
A reference method that specifically measures hemoglobin (Hb) A1c is an essential part of the reference system for the international standardization of Hb A1c/glycohemoglobin. We have developed a new method for quantification, based on the specific N-terminal residue of the hemoglobin β-chains. Enzymatic cleavage of the intact hemoglobin molecule with endoproteinase Glu-C has been optimized to obtain the β-N-terminal hexapeptides of Hb A1c and Hb A0. These peptides have been separated by reversed-phase HPLC and quantitated by electrospray ionization-mass spectrometry (method A) or by capillary electrophoresis (method B). With these peptides and hyphenated separation techniques, it has been possible to overcome the insufficient resolution of currently used protein separation systems for Hb A1c.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Significance of HbA1c Test in Diagnosis and Prognosis of Diabetic Patients
Sherwani, S. I., Khan, H. A., Ekhzaimy, A., Masood, A., & Sakharkar, M. K. (2016) · Biomarker Insights · doi:10.4137/bmi.s38440 · Cited by 1,381
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Hoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
Self-citationApproved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655
Self-citation
Metadata
- Authors
- Kobold, U., Jeppsson, J.-O., Dülffer, T., Finke, A., Hoelzel, W., & Miedema, K.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-10-01
- Volume
- 43
- Issue
- 10
- Pages
- 1944-1951
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1931586538
- Cited by
- 181
- References
- 1
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Candidate reference methods for hemoglobin A1c based on peptide mapping. https://app.cochat.ai/papers/10.1093/clinchem/43.10.1944
- The paper
- Kobold, U., Jeppsson, J.-O., Dülffer, T., Finke, A., Hoelzel, W., & Miedema, K. (1997). Candidate reference methods for hemoglobin A1c based on peptide mapping. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.10.1944
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.