Development and validation of sensitive method for determination of serum cotinine in smokers and nonsmokers by liquid chromatography/atmospheric pressure ionization tandem mass spectrometry
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
We describe a sensitive and specific method for measuring cotinine in serum by HPLC coupled to an atmospheric pressure chemical ionization tandem mass spectrometer. This method can analyze 100 samples/day on a routine basis, and its limit of detection of 50 ng/L makes it applicable to the analysis of samples from nonsmokers potentially exposed to environmental tobacco smoke. Analytical accuracy has been demonstrated from the analysis of NIST cotinine standards and from comparative analyses by both the current method and gas chromatography/high-resolution mass spectrometry. Precision has been examined through the repetitive analysis of a series of bench and blind QC materials. This method has been applied to the analysis of cotinine in serum samples collected as part of the Third National Health and Nutrition Examination Survey (NHANES III).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics for Analytical Chemistry
Miller, J. C., Miller, J., & Worsfold, P. J. (1993) · Medical Entomology and Zoology · Cited by 3,928
Recommendations for the definition, estimation and use of the detection limit
(1987) · The Analyst · doi:10.1039/an9871200199 · Cited by 1,091
Comparison of tests used to distinguish smokers from nonsmokers
Jarvis, M. J., Tunstall-Pedoe, H., Feyerabend, C., Vesey, C., & Saloojee, Y. (1987) · American Journal of Public Health · doi:10.2105/ajph.77.11.1435 · Cited by 994 · cited 1×
“The highest serum cotinine concentration that would be expected in a nonsmoker exposed to ETS is �10–13 �g/L [37, 38], whereas most active smokers have serum cotinine con centrations considerably �25 �g/L.”
BackgroundPirkle, J. L. (1996) · JAMA · doi:10.1001/jama.275.16.1233 · Cited by 704
Self-citationQuality assurance of chemical measurements
Taylor, J. K., & Tranter, R. L. (1989) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80373-6 · Cited by 689
The Human Costs of Tobacco Use
Bartecchi, C. E., MacKenzie, T. D., & Schrier, R. W. (1994) · New England Journal of Medicine · doi:10.1056/nejm199403313301307 · Cited by 534
Cotinine disposition and effects
Benowitz, N. L., Kuyt, F., Jacob, P., Jones, R. T., & Osman, A.-L. (1983) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1983.222 · Cited by 484
Jacob, P., Wilson, M., & Benowitz, N. L. (1981) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)81033-6 · Cited by 448
Sample design: Third National Health and Nutrition Examination Survey.
Ezzati, T. M., Massey, J. T., Waksberg, J., Chu, A., & Maurer, K. R. (1992) · PubMed · Cited by 326
The chemistry of environmental tobacco smoke : composition and measurement
Guerin, M. R., Jenkins, R. A., & Tomkins, B. A. (1992) · Lewis Publishers eBooks · Cited by 324
Jarvis, M. J., Russell, M. A., Benowitz, N. L., & Feyerabend, C. (1988) · American Journal of Public Health · doi:10.2105/ajph.78.6.696 · Cited by 311
Feyerabend, C., & Russell, M. A. H. (1990) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.1990.tb06592.x · Cited by 310
Statistics for analytical chemistry (2nd edn)
Burns, D. T. (1988) · Endeavour · doi:10.1016/0160-9327(88)90144-5 · Cited by 264
Cotinine in the serum, saliva, and urine of nonsmokers, passive smokers, and active smokers.
Wall, M. A., Johnson, J., Jacob, P., & Benowitz, N. L. (1988) · American Journal of Public Health · doi:10.2105/ajph.78.6.699 · Cited by 240
Jacob, P., Yu, L., Wilson, M., & Benowitz, N. L. (1991) · Biological Mass Spectrometry · doi:10.1002/bms.1200200503 · Cited by 234
Nicotine and cotinine elimination pharmacokinetics in smokers and nonsmokers
Benowitz, N. L., & Jacob III, P. (1993) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1993.27 · Cited by 232 · cited 2×
“By contrast, cotinine has a much longer half-life of �18 –20 h, making it more appropriate for use as an exposure marker [7].”
BackgroundHariharan, M., VanNoord, T., & Greden, J. F. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.4.724 · Cited by 183
The use of biologic fluid samples in assessing tobacco smoke consumption.: (475382004-001)
Benowitz, N. L. (1983) · PsycEXTRA Dataset · doi:10.1037/e475382004-001 · Cited by 166
[48] Radioimmunoassay of nicotine, cotinine, and γ3-Pyridyl)-γ-oxo-N-methylbutyramidle
Langone, J. J., & VanVunakis, H. (1982) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(82)84050-0 · Cited by 139
Curvall, M., Vala, E. K., & Enzell, C. R. (1982) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)84168-7 · Cited by 118
Chemical composition of environmental tobacco smoke. 1. Gas-phase acids and bases
Eatough, D. J., Benner, C. L., Bayona, J. M., Richards, G. H., Lamb, J. D., Lee, M. L., Lewis, E. A. S., & Hansen, L. D. (1989) · Environmental Science & Technology · doi:10.1021/es00064a006 · Cited by 94
A vapour dilution system for detector calibration
Fowlis, I. A., & Scott, R. P. W. (1963) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)80860-8 · Cited by 93
Improved 125I radioimmunoassay for cotinine by selective removal of bridge antibodies.
Knight, G. J., Wylie, P., Holman, M. S., & Haddow, J. E. (1985) · Clinical Chemistry · doi:10.1093/clinchem/31.1.118 · Cited by 86
Bjercke, R. J., Cook, G. L., Rychlik, N., Gjika, H. B., Vunakis, H. V., & Langone, J. J. (1986) · Journal of Immunological Methods · doi:10.1016/0022-1759(86)90077-3 · Cited by 86
Chemical composition of environmental tobacco smoke. 2. Particulate-phase compounds
Benner, C. L., Bayona, J. M., Caka, F. M., Tang, H., Lewis, L. J., Crawford, J. W., Lamb, J. D., Lee, M. L., & Lewis, E. A. S. (1989) · Environmental Science & Technology · doi:10.1021/es00064a007 · Cited by 83
Quantification of cotinine in plasma and saliva by liquid chromatography.
Machacek, D., & Jiang, N. S. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.6.979 · Cited by 73
A physiologically based pharmacokinetic model for nicotine and cotinine in man
Robinson, D. E., Balter, N. J., & Schwartz, S. L. (1992) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01064421 · Cited by 56
Improved method for routine determination of nicotine and its main metabolites in biological fluids
Stehlik, G., Kainzbauer, J., Tausch, H., & Richter, O. (1982) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)84169-9 · Cited by 27
Teeuwen, H. W. A., Aalders, R. J. W., & van Rossum, J. M. (1988) · Molecular Biology Reports · doi:10.1007/bf00444313 · Cited by 20
Comparison of the measurement of serum cotinine levels by gas chromatography and radioimmunoassay
Anderson, I. G. M., Proctor, C., & Husager, L. (1991) · The Analyst · doi:10.1039/an9911600691 · Cited by 17
A cotinine in freeze-dried urine reference material
Sander, L. C., & Byrd, G. D. (1989) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.094.028 · Cited by 6
Cited by
Prenatal Exposure to PBDEs and Neurodevelopment
Herbstman, J. B., Sjödin, A., Kurzon, M., Lederman, S. A., Jones, R. S., Rauh, V., Needham, L. L., Tang, D., Niedzwiecki, M., Wang, R. Y., et al. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.0901340 · Cited by 689
Self-citationBenowitz, N. L., Bernert, J. T., Caraballo, R. S., Holiday, D. B., & Wang, J. (2009) · American Journal of Epidemiology · doi:10.1093/aje/kwn301 · Cited by 672
Self-citationPerera, F. P., Rauh, V., Tsai, W.-Y., Kinney, P., Camann, D., Barr, D., Bernert, T., Garfinkel, R., Tu, Y.-H., Diaz, D., et al. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.5742 · Cited by 625
“Plasma cotinine was analyzed by the CDC using high-performance liquid chromatography atmospheric-pressure ionization tandem mass spectrometry as described (Bernert et al. 1997, 2000).”
MethodApelberg, B. J., Witter, F. R., Herbstman, J. B., Calafat, A. M., Halden, R. U., Needham, L. L., & Goldman, L. R. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.10334 · Cited by 617
Self-citationSchleicher, R. L., Carroll, M. D., Ford, E. S., & Lacher, D. A. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.27016 · Cited by 504
Metadata
- Authors
- Bernert, J. T., Turner, W. E., Pirkle, J. L., Sosnoff, C. S., Akins, J. R., Waldrep, M. K., Ann, Q., Covey, T. R., Whitfield, W. E., Gunter, E. W., Miller, B. B., Patterson, D. G., Needham, L. L., Hannon, W. H., & Sampson, E. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-12-01
- Volume
- 43
- Issue
- 12
- Pages
- 2281-2291
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2154694813
- Cited by
- 337
- References
- 31
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.