The DOI matches its Crossref record.
A high-performance liquid-chromatographic method for routine simultaneous determination of nicotine and cotinine in plasma.
Abstract
We describe a rapid, sensitive method for the routine simultaneous determination of nicotine and cotinine in 1 mL of plasma. Extraction in 10-mL screw-capped Teflon tubes with methylene chloride after deproteinization with trichloroacetic acid eliminated emulsion formation. The extract, after evaporation and reconstitution in 30 microL of mobile phase, is injected into a reversed-phase C-18 ion-pair column of an isocratic high-performance liquid-chromatographic unit. Absorbance is monitored at 256 nm. The mobile phase is a citrate-phosphate (30 mmol each per liter) buffer mixture containing 50 mL of acetonitrile and 1 mmol of sodium heptanesulfonate per liter. 2-Phenylimidazole is the internal standard. The detection limit is 1 microgram/L for nicotine and 3 micrograms/L for cotinine. The standard curve is linear from 0 to 700 micrograms/L for both compounds. The average CV for nicotine in the concentration range 0-100 micrograms/L is 6.5%, and that for cotinine in the concentration range 50-700 micrograms/L is 4%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biochemical verification of tobacco use and cessation
Benowitz, N. L., III, P. J., Ahijevych, K., Jarvis, M. J., Hall, S., LeHouezec, J., Hansson, A., Lichtenstein, E., Henningfield, J., Tsoh, J., et al. (2002) · Nicotine & Tobacco Research · doi:10.1080/14622200210123581 · Cited by 1,800
Pomerleau, C. S., Carton, S. M., Lutzke, M. L., Flessland, K. A., & Pomerleau, O. F. (1994) · Addictive Behaviors · doi:10.1016/0306-4603(94)90049-3 · Cited by 729
Bernert, J. T., Turner, W. E., Pirkle, J. L., Sosnoff, C. S., Akins, J. R., Waldrep, M. K., Ann, Q., Covey, T. R., Whitfield, W. E., Gunter, E. W., et al. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.12.2281 · Cited by 337
Sacco, K. A., Termine, A., Seyal, A., Dudas, M. M., Vessicchio, J. C., Krishnan-Sarin, S., Jatlow, P. I., Wexler, B. E., & George, T. P. (2005) · Archives of General Psychiatry · doi:10.1001/archpsyc.62.6.649 · Cited by 330
Stress decreases the ability to resist smoking and potentiates smoking intensity and reward
McKee, S. A., Sinha, R., Weinberger, A. H., Sofuoglu, M., Harrison, E. L., Lavery, M., & Wanzer, J. (2011) · Journal of Psychopharmacology · doi:10.1177/0269881110376694 · Cited by 276
Metadata
- Authors
- Hariharan, M., VanNoord, T., & Greden, J. F.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-04-01
- Volume
- 34
- Issue
- 4
- Pages
- 724-729
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4299701462
- Cited by
- 183
- References
- 0
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A high-performance liquid-chromatographic method for routine simultaneous determination of nicotine and cotinine in plasma. https://app.cochat.ai/papers/10.1093/clinchem/34.4.724
- The paper
- Hariharan, M., VanNoord, T., & Greden, J. F. (1988). A high-performance liquid-chromatographic method for routine simultaneous determination of nicotine and cotinine in plasma. Clinical Chemistry. https://doi.org/10.1093/clinchem/34.4.724
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.