Amino acid determination in biological fluids by automated ion-exchange chromatography: performance of Hitachi L-8500A
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The Hitachi L-8500A is a newly available apparatus for amino acid (AA)analysis that allows automatic on-line mixing of the ninhydrin reagent. The within-run precision (human plasma pools at three different concentrations) showed CVs <3.8% except for the lowest concentration of citrulline (4.4%), Tyr (4.5%), and α-aminobutyric acid (7.6%), and for the intermediate concentration of Asp (8.7%). Between-run precision (CV) was <3.1% for 17 AAs and <8.0% for 24 of 25 AAs (CV Asp = 12.0%). For retention times, within-run precision was <0.4% and between-run precision <1.8%. Excellent relations were found between the results from the Hitachi L-8500A and the widely used Beckman 6300 analyzer (0.929≤ r ≤0.999). The detection was still linear at 5 μmol/L except for Pro and hydroxyproline (20 μmol/L). The upper limit was at least 2500 μmol/L for 13 AAs and at least 1000 μmol/L for 27 of 29 AAs (anserine = 500, Val = 600 μmol/L). Values from 100 human plasma samples agreed with previously published data. We conclude that the results obtained with the Hitachi L-8500A are satisfactory when compared with those of other AA analyzers utilizing the same method. Furthermore, the Hitachi L-8500A displays several advantages including programming flexibility, microsample capacity, low noise plotting, ammonia filtering, and manual repacking of the analytical column.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chromatography of Amino Acids on Sulfonated Polystyrene Resins. An Improved System
Moore, S., Spackman, D. H., & Stein, W. H. (1958) · Analytical Chemistry · doi:10.1021/ac60139a005 · Cited by 2,196 · cited 2×
“The classic ion-exchange separation followed by postcolumn derivatization with ninhydrin has been considerably improved since its initial inception [13], particularly with availability of modern dedicated AA analyzers [14, 15].”
BackgroundMethodCHROMATOGRAPHY OF AMINO ACIDS ON SULFONATED POLYSTYRENE RESINS
Moore, S., & Stein, W. H. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)77791-6 · Cited by 1,768
Einarsson, S., Josefsson, B., & Lagerkvist, S. (1983) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)91638-8 · Cited by 554 · cited 1×
“INDEXING TERMS: ninhydrin reaction • cation-exchange chromatography • analytical performance evaluation Several methods are suitable for the determination of amino acids (AAs) in biological fluids, including gas chromatography [1, 2], reversed-phase chromatography with precolumn derivatization with various reagents su…”
MethodFekkes, D., van Dalen, A., Edelman, M., & Voskuilen, A. (1995) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/0378-4347(95)00111-u · Cited by 161 · cited 2×
“Furthermore, in our study, the mean concentration for Glu was specifically low, but the total of Glu plus Gln was in agreement with other studies [4, 5, 21].”
ResultFully automated liquid-chromatographic determination of amino acids.
van Eijk, H. M., van der Heijden, M. A., van Berlo, C. L., & Soeters, P. B. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.12.2510 · Cited by 99
Dorresteijn, R. C., Berwald, L., Zomer, G., de Gooijer, C. D., Wieten, G., & Beuvery, E. C. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00927-2 · Cited by 95
Automatic amino acid analysis utilizing 4-fluoro-7-nitrobenzo-2-oxa-1,3-diazole
Kotaniguchi, H., Kawakatsu, M., Toyo’oka, T., & Imai, K. (1987) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/0378-4347(87)80164-0 · Cited by 44 · cited 1×
“INDEXING TERMS: ninhydrin reaction • cation-exchange chromatography • analytical performance evaluation Several methods are suitable for the determination of amino acids (AAs) in biological fluids, including gas chromatography [1, 2], reversed-phase chromatography with precolumn derivatization with various reagents su…”
MethodFeste, A. S. (1992) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/0378-4347(92)80094-7 · Cited by 42 · cited 3×
“INDEXING TERMS: ninhydrin reaction • cation-exchange chromatography • analytical performance evaluation Several methods are suitable for the determination of amino acids (AAs) in biological fluids, including gas chromatography [1, 2], reversed-phase chromatography with precolumn derivatization with various reagents su…”
MethodResultZiegler, F., Boucher, J. L., Coudray‐Lucas, C., & Cynober, L. (1992) · Journal of Analytical Methods in Chemistry · doi:10.1155/s1463924692000270 · Cited by 29 · cited 3×
“Lewis et al. [1 ]( n5 7) Labadarios et al. [2 ]( n5 10) Cynober et al. [21 ]( n5 70) Fekkes et al. [5 ]( n5 44) Ziegler et al. [ 4 ]( n5 27) Feste [9 ]( n5 24)”
ResultInfluentialSelf-citationPractical gas—liquid chromatographic method for the determination of amino acids in human serum
Yamamoto, S., Kiyama, S., Watanabe, Y., & Makita, M. (1982) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)81729-6 · Cited by 24 · cited 1×
“Collectively, the results of the between-run precision assays were satisfactory and close to or even better than those obtained by classic ion-exchange chromatography [14, 19], other HPLC techniques [8–10, 12], or gas chromatography [20].”
Result
Cited by
[60]Fullerene is a Powerful Antioxidant in Vivo with No Acute or Subacute Toxicity
Gharbi, N., Pressac, M., Hadchouel, M., Szwarc, H., Wilson, S. R., & Moussa, F. (2005) · Nano Letters · doi:10.1021/nl051866b · Cited by 656
Friedman, M. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030490p · Cited by 647
Citrulline as a biomarker of intestinal failure due to enterocyte mass reduction
Crenn, P., Messing, B., & Cynober, L. (2008) · Clinical Nutrition · doi:10.1016/j.clnu.2008.02.005 · Cited by 586
Self-citationAlmost all about citrulline in mammals
Curis, E., Nicolis, I., Moinard, C., Osowska, S., Zerrouk, N., Bénazeth, S., & Cynober, L. (2005) · Amino Acids · doi:10.1007/s00726-005-0235-4 · Cited by 571
Self-citationCrenn, P., Coudray–Lucas, C., Thuillier, F., Cynober, L., & Messing, B. (2000) · Gastroenterology · doi:10.1053/gast.2000.20227 · Cited by 498
Self-citationPlasma citrulline: a marker of enterocyte mass in villous atrophy-associated small bowel disease
Crenn, P., Vahedi, K., Lavergne-Slove, A., Cynober, L., Matuchansky, C., & Messing, B. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00170-7 · Cited by 347
Self-citationCynober, L. A. (2002) · Nutrition · doi:10.1016/s0899-9007(02)00780-3 · Cited by 303
Self-citationSeguy, D., Vahedi, K., Kapel, N., Souberbielle, J., & Messing, B. (2003) · Gastroenterology · doi:10.1053/gast.2003.50057 · Cited by 234
Advances in amino acid analysis
Kaspar, H., Dettmer, K., Gronwald, W., & Oefner, P. J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2421-1 · Cited by 232
Automated GC–MS analysis of free amino acids in biological fluids
Kaspar, H., Dettmer, K., Gronwald, W., & Oefner, P. J. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.06.018 · Cited by 180
Urinary amino acid analysis: A comparison of iTRAQ®–LC–MS/MS, GC–MS, and amino acid analyzer
Kaspar, H., Dettmer, K., Chan, Q., Daniels, S., Nimkar, S., Daviglus, M. L., Stamler, J., Elliott, P., & Oefner, P. J. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.05.019 · Cited by 172
Citrulline increases arginine pools and restores nitrogen balance after massive intestinal resection
Osowska, S., Moinard, C., Loï, C., Neveux, N., & Cynober, L. (2004) · Gut · doi:10.1136/gut.2004.042317 · Cited by 160
Self-citationKoglin, N., Mueller, A., Berndt, M., Schmitt-Willich, H., Toschi, L., Stephens, A. W., Gekeler, V., Friebe, M., & Dinkelborg, L. M. (2011) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-11-0687 · Cited by 120
Metadata
- Authors
- Le Boucher, J., Charret, C., Coudray-Lucas, C., Giboudeau, J., & Cynober, L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-08-01
- Volume
- 43
- Issue
- 8
- Pages
- 1421-1428
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2101463846
- Cited by
- 224
- References
- 10
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.