Urinary amino acid analysis: A comparison of iTRAQ®–LC–MS/MS, GC–MS, and amino acid analyzer
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Automatic Recording Apparatus for Use in Chromatography of Amino Acids
Spackman, D. H., Stein, W. H., & Moore, S. (1958) · Analytical Chemistry · doi:10.1021/ac60139a006 · Cited by 9,585
Kinetics and Kinematics for Translational Motions in Microgravity During Parabolic Flight
Stirling, L., Willcox, K., Ferguson, P., & Newman, D. (2009) · Aviation, Space, and Environmental Medicine · doi:10.3357/asem.2356.2009 · Cited by 5,259
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Self-citationINTERMAP: background, aims, design, methods, and descriptive statistics (nondietary)
Stamler, J., Elliott, P., Dennis, B., Dyer, A., Kesteloot, H., Liu, K., Ueshima, H., Zhou, B., & for the INTERMAP Research Group (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001603 · Cited by 280
Self-citationInborn Errors of Metabolism in Infancy: A Guide to Diagnosis
Burton, B. K. (1998) · Pediatrics · doi:10.1542/peds.102.6.e69 · Cited by 279
Advances in amino acid analysis
Kaspar, H., Dettmer, K., Gronwald, W., & Oefner, P. J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2421-1 · Cited by 232
Self-citationLe Boucher, J., Charret, C., Coudray-Lucas, C., Giboudeau, J., & Cynober, L. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1421 · Cited by 224
Inborn errors of metabolism in infancy-A guide to diagnosis
(2000) · The Indian Journal of Pediatrics · doi:10.1007/bf02802624 · Cited by 216
Cited by
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Erarpat, S., Bodur, S., Öztürk Er, E., & Bakırdere, S. (2020) · Journal of Separation Science · doi:10.1002/jssc.201901078 · Cited by 18
Metadata
- Authors
- Kaspar, H., Dettmer, K., Chan, Q., Daniels, S., Nimkar, S., Daviglus, M. L., Stamler, J., Elliott, P., & Oefner, P. J.
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 877
- Issue
- 20-21
- Pages
- 1838-1846
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W2088546724
- Cited by
- 172
- References
- 18
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Urinary amino acid analysis: A comparison of iTRAQ®–LC–MS/MS, GC–MS, and amino acid analyzer. https://app.cochat.ai/papers/10.1016/j.jchromb.2009.05.019
- The paper
- Kaspar, H., Dettmer, K., Chan, Q., Daniels, S., Nimkar, S., Daviglus, M. L., Stamler, J., Elliott, P., & Oefner, P. J. (2009). Urinary amino acid analysis: A comparison of iTRAQ®–LC–MS/MS, GC–MS, and amino acid analyzer. Journal of Chromatography B. https://doi.org/10.1016/j.jchromb.2009.05.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.