Serum CrossLaps One Step ELISA. First application of monoclonal antibodies for measurement in serum of bone-related degradation products from C-terminal telopeptides of type I collagen

Rosenquist, Christian, Fledelius, Christian, Christgau, Stephan, Pedersen, Brian J, Bonde, Martin, Qvist, Per, Christiansen, Claus·1998·Clinical Chemistry

Abstract

We have developed a two-site ELISA for measurement in serum of bone-related degradation products derived from C-terminal telopeptides of type I collagen. The assay is based on the application of two highly specific monoclonal antibodies against the amino acid sequence of AHD-β-GGR, where the aspartic acid residue (D) is β-isomerized. In a one-step incubation procedure, the degradation products containing cross-linked diisomerized EKAHD-β-GGR peptides are captured by a biotinylated antibody and a peroxidase-conjugated antibody. The generated complex is then bound to the streptavidin surface via the biotin conjugate. Desalted urinary antigens are used for standardization, and parallelism is observed with serum samples. Results are obtained in <2.5 h, and both inter- and intraassay imprecision are <8%. The serum CrossLaps™ concentration was 1748 ± 740 pmol/L (mean ± SD) in premenopausal women (n = 65) and 2952 ± 1325 pmol/L in a group of healthy postmenopausal women (n = 169). The Serum CrossLaps One Step ELISA was capable of detecting a highly significant (P <0.001) effect of hormone replacement therapy in a retrospective study involving 22 postmenopausal women.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/44.11.2281

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 318

Metadata

Authors
Rosenquist, C., Fledelius, C., Christgau, S., Pedersen, B. J., Bonde, M., Qvist, P., & Christiansen, C.
Venue
Clinical Chemistry
Published
1998-11-01
Volume
44
Issue
11
Pages
2281-2289
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1952385262
Cited by
318
References
23
FWCI
15.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Serum CrossLaps One Step ELISA. First application of monoclonal antibodies for measurement in serum of bone-related degradation products from C-terminal telopeptides of type I collagen. https://app.cochat.ai/papers/10.1093/clinchem/44.11.2281
The paper
Rosenquist, C., Fledelius, C., Christgau, S., Pedersen, B. J., Bonde, M., Qvist, P., & Christiansen, C. (1998). Serum CrossLaps One Step ELISA. First application of monoclonal antibodies for measurement in serum of bone-related degradation products from C-terminal telopeptides of type I collagen. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.11.2281

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.