Positive Interference of Icodextrin Metabolites in Some Enzymatic Glucose Methods
The DOI matches its Crossref record.
Abstract
The glucose polymer icodextrin has become widely used in continuous ambulatory peritoneal dialysis (CAPD) (1). Icodextrin is hydrolyzed in the systemic circulation to oligosaccharides such as maltose, maltotriose, and maltotetraose. The use of icodextrin leads to substantial concentrations of these icodextrin metabolites in the blood, where they are not normally found (2). The presence of these metabolites could have an effect on enzymatic glucose measurement. A common complication in diabetes mellitus patients is renal insufficiency, which may lead to dialysis. Patients with diabetes mellitus treated by icodextrin-CAPD are at risk for having erroneous blood glucose measurements. To evaluate the possibility of interference of the icodextrin metabolites in various glucose assays, glucose was measured in 2–11 sets of four heparinized blood samples (800 μL); each set was obtained from a single specimen. These samples were supplemented with 10 μL of 9 g/L NaCl solution as a blank sample or 10 μL of a solution of maltose, maltotriose, or maltotetraose (all sugars from Sigma Chemical Co.), achieving final concentrations for the icodextrin metabolites of 1.2, 1.2, and 0.6 g/L, respectively. These icodextrin metabolite concentrations were reported to be the maximum reachable concentrations in vivo (2). From each sample, 100 μL was centrifuged and analyzed on a Hitachi 911 with a plasma glucose dehydrogenase (GDH) method (Boehringer Mannheim). The whole blood samples were analyzed using an EML 105 with a glucose oxidase (GOD) membrane method (Radiometer), a Chiron 865 with a GOD membrane method accompanied by a glucose reference electrode, and bedside glucose analyzers: Accutrend Sensor with a bioamperometric GDH method (Boehringer Mannheim), Glucocard Memory with a bioamperometric GOD method (Menarini Diagnostics), Glucotouch with a colorimetric GOD method (Lifescan, Johnson & Johnson), One Touch Profile with a colorimetric GOD method (Lifescan), One Touch II with a colorimetric GOD method (Lifescan), and Precision with a GOD method (Medisense). The results of the samples containing icodextrin metabolites were compared with the blank sample and expressed as a mean difference. Interference was defined as a mean difference >0.5 mmol/L (Table 1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
“GDH-PQQ catalyzes not only the oxidation of glucose, but also of other sugars, such as maltose, maltriose, maltotetraose, and icodextrin (Extraneal; Baxter, Brussels, Belgium) [108-110].”
BackgroundEnzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird's Eye View of Glucose Sensing Enzymes
Ferri, S., Kojima, K., & Sode, K. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500507 · Cited by 471
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Performance of a new interference-resistant glucose meter
Vanavanan, S., Santanirand, P., Chaichanajarernkul, U., Chittamma, A., DuBois, J. A., Shirey, T., & Heinz, M. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.09.010 · Cited by 39
“The maltose effect on glucose measurement has been demonstrated by Janssen et al [37].”
Method
Metadata
- Authors
- Janssen, W., Harff, G., Caers, M., & Schellekens, A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-11-01
- Volume
- 44
- Issue
- 11
- Pages
- 2379-2380
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1953705795
- Cited by
- 71
- References
- 0
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Positive Interference of Icodextrin Metabolites in Some Enzymatic Glucose Methods. https://app.cochat.ai/papers/10.1093/clinchem/44.11.2379
- The paper
- Janssen, W., Harff, G., Caers, M., & Schellekens, A. (1998). Positive Interference of Icodextrin Metabolites in Some Enzymatic Glucose Methods. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.11.2379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.