Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours

Chace, Donald H, Sherwin, John E, Hillman, Steven L, Lorey, Fred, Cunningham, George C·1998·Clinical Chemistry

Abstract

We compared the screening interpretation of fluorometric analytical results for phenylketonuria (PKU) with tandem mass spectrometry (MS/MS) in filter paper blood spots collected from newborns <24 h of age. In MS/MS, both Phe and Tyr are quantified. Two hundred and eight blood spots collected from infants <24 h of age were retrieved from storage from the California newborn screening program. These samples had been categorized on the basis of fluorometric analysis as initial negative, initial positive for hyperphenylalaninemia with negative determination on recall, or initial positive for hyperphenylalaninemia and confirmed on follow up as PKU or variant hyperphenylalaninemia. The retrieved samples were analyzed in a blinded fashion using MS/MS. Correlation analysis of fluorometry vs MS/MS for Phe concentration was high, with a Pearson correlation coefficient of 0.817. When 180 μmol/L was used as the cutoff Phe concentration for MS/MS and 258 μmol/L was used as the cutoff for fluorometry, all infants with confirmed classical PKU and variant hyperphenylalaninemia were detected. MS/MS analysis reduced the number of false-positive results from 91 to 3. Simultaneous quantification of Phe and Tyr by MS/MS with the use of a cutoff Phe/Tyr molar ratio of 2.5 further reduced the number of false positives to 1. Samples from affected infants showed a discernible trend of increasing Phe concentration and Phe/Tyr molar ratio with age of collection. These results demonstrate the utility of MS/MS in the routine PKU screening of early-discharge newborns. MS/MS reduces the false-positive rate of fluorometric screening almost 100-fold because of the improved accuracy and precision of Phe measurement and simultaneous confirmation with the Phe/Tyr molar ratio. In addition to the detection of PKU, MS/MS can also detect other aminoacidopathies and disorders of fatty acid and organic acid metabolism with lower false-positive rates than other methods currently used in newborn screening programs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/44.12.2405

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Chace, D. H., Sherwin, J. E., Hillman, S. L., Lorey, F., & Cunningham, G. C.
Venue
Clinical Chemistry
Published
1998-12-01
Volume
44
Issue
12
Pages
2405-2409
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2141200554
Cited by
182
References
0
FWCI
5.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours. https://app.cochat.ai/papers/10.1093/clinchem/44.12.2405
The paper
Chace, D. H., Sherwin, J. E., Hillman, S. L., Lorey, F., & Cunningham, G. C. (1998). Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.12.2405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.