Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours
The DOI matches its Crossref record.
Abstract
We compared the screening interpretation of fluorometric analytical results for phenylketonuria (PKU) with tandem mass spectrometry (MS/MS) in filter paper blood spots collected from newborns <24 h of age. In MS/MS, both Phe and Tyr are quantified. Two hundred and eight blood spots collected from infants <24 h of age were retrieved from storage from the California newborn screening program. These samples had been categorized on the basis of fluorometric analysis as initial negative, initial positive for hyperphenylalaninemia with negative determination on recall, or initial positive for hyperphenylalaninemia and confirmed on follow up as PKU or variant hyperphenylalaninemia. The retrieved samples were analyzed in a blinded fashion using MS/MS. Correlation analysis of fluorometry vs MS/MS for Phe concentration was high, with a Pearson correlation coefficient of 0.817. When 180 μmol/L was used as the cutoff Phe concentration for MS/MS and 258 μmol/L was used as the cutoff for fluorometry, all infants with confirmed classical PKU and variant hyperphenylalaninemia were detected. MS/MS analysis reduced the number of false-positive results from 91 to 3. Simultaneous quantification of Phe and Tyr by MS/MS with the use of a cutoff Phe/Tyr molar ratio of 2.5 further reduced the number of false positives to 1. Samples from affected infants showed a discernible trend of increasing Phe concentration and Phe/Tyr molar ratio with age of collection. These results demonstrate the utility of MS/MS in the routine PKU screening of early-discharge newborns. MS/MS reduces the false-positive rate of fluorometric screening almost 100-fold because of the improved accuracy and precision of Phe measurement and simultaneous confirmation with the Phe/Tyr molar ratio. In addition to the detection of PKU, MS/MS can also detect other aminoacidopathies and disorders of fatty acid and organic acid metabolism with lower false-positive rates than other methods currently used in newborn screening programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Use of Tandem Mass Spectrometry for Multianalyte Screening of Dried Blood Specimens from Newborns
Chace, D. H., Kalas, T. A., & Naylor, E. W. (2003) · Clinical Chemistry · doi:10.1373/clinchem.2003.022178 · Cited by 621
Self-citationMass spectrometry in metabolome analysis
Villas‐Bôas, S. G., Mas, S., Åkesson, M., Smedsgaard, J., & Nielsen, J. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20032 · Cited by 616
Schulze, A., Lindner, M., Kohlmüller, D., Olgemöller, K., Mayatepek, E., & Hoffmann, G. F. (2003) · Pediatrics · doi:10.1542/peds.111.6.1399 · Cited by 519
Zytkovicz, T. H., Fitzgerald, E. F., Marsden, D., Larson, C. A., Shih, V. E., Johnson, D. M., Strauss, A. W., Comeau, A. M., Eaton, R. B., & Grady, G. F. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.11.1945 · Cited by 505
Metabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Panel, N. I. O. H. C. D. (2001) · Pediatrics · doi:10.1542/peds.108.4.972 · Cited by 274
Piraud, M., Vianey‐Saban, C., Petritis, K., Elfakir, C., Steghens, J., Morla, A., & Bouchu, D. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1054 · Cited by 266
Blau, N., Hennermann, J. B., Langenbeck, U., & Lichter-Konecki, U. (2011) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2011.08.017 · Cited by 262
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Phenylketonuria Scientific Review Conference: State of the science and future research needs
Camp, K. M., Parisi, M. A., Acosta, P. B., Berry, G. T., Bilder, D. A., Blau, N., Bodamer, O. A., Brosco, J. P., Brown, C. S., Burlina, A. B., et al. (2014) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2014.02.013 · Cited by 261
Serving the Family From Birth to the Medical Home
From the AAP Newborn Screening Task Force, E. G. V. (2000) · Pediatrics · doi:10.1542/peds.106.s2.389 · Cited by 244
Exploring Disease through Metabolomics
Vinayavekhin, N., Homan, E. A., & Saghatelian, A. (2010) · ACS Chemical Biology · doi:10.1021/cb900271r · Cited by 230
Mass Spectrometry in the Clinical Laboratory
Chace, D. H. (2001) · Chemical Reviews · doi:10.1021/cr990077+ · Cited by 214
Self-citationChace, D. H., Kalas, T. A., & Naylor, E. W. (2002) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev.genom.3.022502.103213 · Cited by 210
Self-citationPandor, A., Eastham, J., Beverley, C., Chilcott, J., & Paisley, S. (2004) · Health Technology Assessment · doi:10.3310/hta8120 · Cited by 201
Metadata
- Authors
- Chace, D. H., Sherwin, J. E., Hillman, S. L., Lorey, F., & Cunningham, G. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-12-01
- Volume
- 44
- Issue
- 12
- Pages
- 2405-2409
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2141200554
- Cited by
- 182
- References
- 0
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.