The DOI matches its Crossref record.
A non-(1–84) circulating parathyroid hormone (PTH) fragment interferes significantly with intact PTH commercial assay measurements in uremic samples
Abstract
We have previously shown that the Nichols assay for intact parathyroid hormone (I-PTH) reacts with a non-(1–84) molecular form of PTH. This form behaves as a carboxy-terminal fragment and accumulates in renal failure, accounting for 40–60% of the measured immunoreactivity. We wanted to see whether this was a common event with other commercial two-site I-PTH assays. We thus compared the ability of three commercial kits [Nichols (NL), Incstar (IT), and Diagnostic System Laboratories (DSL)] to measure I-PTH in 112 renal failure patients and to detect hPTH(1–84) and non-(1–84)PTH on HPLC profiles of serum pools from uremic patients with I-PTH concentrations of 10–100 pmol/L. The behavior of synthetic hPTH(7–84), a fragment possibly related to non-(1–84)PTH was also compared with hPTH(1–84) in the three assays. The I-PTH concentrations measured with the three assays in the 112 uremic samples were highly related (r2 ≥ 0.89, P <0.0001), and the values measured with NL were, on average, 23% higher than IT. Values measured with DSL were 23% and 56% higher than IT for values less than and more than 40 pmol/L, respectively. The three assays detected two HPLC peaks on four different profiles corresponding to hPTH(1–84) and non-(1–84)PTH. This last peak represented 36 ± 8.4% of the immunoreactivity with NL, 24 ± 5.5% with IT, and 25 ± 2.8% with DSL (NL vs IT or DSL: P <0.05). These differences were confirmed by a 50% lower immunoreactivity to hPTH(7–84) compared with hPTH(1–84) for IT and DSL but not for NL. These results suggest that most of the two-site I-PTH assays would cross-react with non-(1–84)PTH material, thus explaining about one-half of the 2–2.5 × higher I-PTH concentrations reported in uremic patients without bone involvement than in subjects without uremia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parathyroid hormone: past and present
Potts, J. T. (2005) · Journal of Endocrinology · doi:10.1677/joe.1.06057 · Cited by 327
Persistent Increase in Bone Turnover in Graves’ Patients with Subclinical Hyperthyroidism
Kumeda, Y., Inaba, M., Tahara, H., Kurioka, Y., Ishikawa, T., Morii, H., & Nishizawa, Y. (2000) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.85.11.6979 · Cited by 123
Assessment of ACTH assay variability: a multicenter study
Pecori Giraldi, F., Saccani, A., Cavagnini, F., & _, _. (2011) · European Journal of Endocrinology · doi:10.1530/eje-10-0962 · Cited by 80
Metadata
- Authors
- Lepage, R., Roy, L., Brossard, J.-H., Rousseau, L., Dorais, C., Lazure, C., & D’Amour, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-04-01
- Volume
- 44
- Issue
- 4
- Pages
- 805-809
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1922554536
- Cited by
- 362
- References
- 0
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.