Analytical and clinical performance of a homogeneous enzymatic LDL-cholesterol assay compared with the ultracentrifugation-dextran sulfate-Mg2+ method
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
LDL-cholesterol (LDL-C) concentration is currently determined in most clinical laboratories by the Friedewald calculation. This approach has several limitations and may not meet the current total error requirement in LDL-C measurement of ≤ 12%. We evaluated the analytical and clinical performance of the direct N-geneous LDL-C assay (Equal Diagnostics). The N-geneous method correlated highly with the modified beta-quantification assay (r = 0.95; y = 0.91x + 70.6 mg/L; n = 199), showed no significant effect of increased triglyceride or other common interferants, and performed adequately in serum samples from nonfasting individuals. This assay demonstrated a mean total error of 6.75% over a wide range of LDL-C concentrations. In addition, at the medical decision cutoff points, this LDL-C assay showed positive predictive values of 78–95% and negative predictive values of 84–99%. We conclude that the N-geneous LDL-C meets the currently established analytical performance goals and appears to have a role in the diagnosis and management of hypercholesterolemic patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Criteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
Cited by
Plasma Adiponectin Levels and Risk of Myocardial Infarction in Men
Pischon, T. (2004) · JAMA · doi:10.1001/jama.291.14.1730 · Cited by 1,773
25-Hydroxyvitamin D and Risk of Myocardial Infarction in Men<subtitle>A Prospective Study</subtitle>
Giovannucci, E. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.11.1174 · Cited by 1,141
Impact of HIV infection and HAART on serum lipids in men
Riddler, S. A. (2003) · JAMA · doi:10.1001/jama.289.22.2978 · Cited by 624
“130-159 7 (14) 6 (12) 12 (24) 11 (22) 9 (21) 13 (34)”
Pischon, T., Girman, C. J., Sacks, F. M., Rifai, N., Stampfer, M. J., & Rimm, E. B. (2005) · Circulation · doi:10.1161/circulationaha.104.532499 · Cited by 514
Self-citationNauck, M., Warnick, G. R., & Rifai, N. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.2.236 · Cited by 442
“C within a broad-cut LDL fraction together with the other atherogenic lipoproteins: Lp(a), IDL, and remnants.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Rifai, N., Iannotti, E., DeAngelis, K., & Law, T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-06-01
- Volume
- 44
- Issue
- 6
- Pages
- 1242-1250
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2117194717
- Cited by
- 109
- References
- 1
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.