The DOI matches its Crossref record.
Cardiac troponin T isoforms expressed in renal diseased skeletal muscle will not cause false-positive results by the second generation cardiac troponin T assay by Boehringer Mannheim
Abstract
The purpose of this study was to determine whether the two monoclonal anti-cardiac troponin T (cTnT) antibodies (MAbs) used in the second generation cTnT assay by Boehringer Mannheim (BM, capture Ab, M11.7; detection Ab, M7) would detect cTnT isoforms expressed in human skeletal muscle in response to chronic renal disease (CRD). cTnT expression was examined in skeletal muscle biopsies obtained from 45 CRD patients, as well as nondiseased human heart (n = 3) and skeletal muscle (n = 3). cTnT proteins were resolved by modified 7.5% sodium dodecyl sulfate-polyacrylamide gel electrophoresis, transferred to nitrocellulose, and probed with the following anti-cTnT MAbs: M11.7; M7; JS-2, Lakeland Biomedical; and 13–11, Duke University. All four antibodies detected the cTnT isoforms (Ta, Te) expressed in human myocardium. In 20 of 45 skeletal muscle biopsies, MAb M11.7 recognized its epitope in one to three proteins, molecular mass 34–36 kDa, designated Te, Td, and Tc; the strongest signal was that of Te. The same proteins were recognized by MAbs JS-2 and 13–11. The BM M7 antibody did not detect the cTnT isoforms in the molecular mass range of 34–36 kDa. However, MAb M7 did detect a cTnT isoform, molecular mass 39 kDa, in 2 of 45 biopsies. This isoform had an electrophoretic mobility similar to the predominant heart cTnT isoform, Ta. We conclude that cTnT isoforms are expressed in the skeletal muscle of CRD patients. However, given the epitopes recognized by the BM MAbs M7 and M11.7 and the variable presence of these cTnT isoforms in skeletal muscle, the second generation BM cTnT assay will not detect these isoforms if they are released from skeletal muscle into the circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861
Self-citationTroponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Wu, A. H., Apple, F. S., Gibler, W. B., Jesse, R. L., Warshaw, M. M., & Valdes, R. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1104 · Cited by 662
Self-citationIt’s Time for a Change to a Troponin Standard
Jaffe, A. S., Ravkilde, J., Roberts, R., Naslund, U., Apple, F. S., Galvani, M., & Katus, H. (2000) · Circulation · doi:10.1161/01.cir.102.11.1216 · Cited by 643
Self-citationRecommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Metadata
- Authors
- Ricchiuti, V., Voss, E. M., Ney, A., Odland, M., Anderson, P. A. W., & Apple, F. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-09-01
- Volume
- 44
- Issue
- 9
- Pages
- 1919-1924
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1952836337
- Cited by
- 208
- References
- 0
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac troponin T isoforms expressed in renal diseased skeletal muscle will not cause false-positive results by the second generation cardiac troponin T assay by Boehringer Mannheim. https://app.cochat.ai/papers/10.1093/clinchem/44.9.1919
- The paper
- Ricchiuti, V., Voss, E. M., Ney, A., Odland, M., Anderson, P. A. W., & Apple, F. S. (1998). Cardiac troponin T isoforms expressed in renal diseased skeletal muscle will not cause false-positive results by the second generation cardiac troponin T assay by Boehringer Mannheim. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.9.1919
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.