Mass-sensing, multianalyte microarray immunoassay with imaging detection
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Miniaturization of ligand binding assays may reduce costs by decreasing reagent consumption, but it is less apparent that miniaturized assays can simultaneously exceed the sensitivity of macroscopic techniques by analyte “harvesting” to exploit the total analyte mass available in a sample. Capture reagents (avidin or antibodies) immobilized in 200-μm diameter zones are shown to substantially deplete analyte from a liquid sample during a 1–3-h incubation, and the assays that result sense the total analyte mass in a sample rather than its concentration. Detection of as few as 105 molecules of analyte per zone is possible by fluorescence imaging in situ on the solid phase using a near-infrared dye label. Single and multianalyte mass-sensing sandwich array assays of the IgG subclasses show the sensitivity and specificity of ELISA methods but use less than 1/100 the capture antibody required by the 96-well plate format.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pugliese, L., Coda, A., Malcovati, M., & Bolognesi, M. (1993) · Journal of Molecular Biology · doi:10.1006/jmbi.1993.1321 · Cited by 306 · cited 1×
“of avidin of roughly 190 pg/spot, assuming each avidin molecule occupies 6 nm3 in the dry matrix ( 10 ).”
BackgroundMultianalyte microspot immunoassay--microanalytical "compact disk" of the future
Ekins, R. P., & Chu, F. W. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.11.1955 · Cited by 235
Kinetics of antigen-antibody reactions at solid-liquid interfaces
Stenberg, M., & Nygren, H. (1988) · Journal of Immunological Methods · doi:10.1016/0022-1759(88)90376-6 · Cited by 215 · cited 1×
“By using covalent immobilization, signal losses in wash steps have been found to be unimportant, and we believe that retention of bound analyte on the printed arrays is facilitated by the high local concentration of binding sites experienced by bound species (8, 9).”
BackgroundImmunochemistry at interfaces.
Nygren, H., & Stenberg, M. (1989) · PubMed · Cited by 84
Hamilton, R. G., Wilson, R. W., Spillman, T., & Roebber, M. (1988) · Journal of Immunoassay · doi:10.1080/01971528808053217 · Cited by 23 · cited 2×
“A conventional ELISA plate assay (7) has been reported to have a sensitivity of 2 mg/L,”
Background
Cited by
Haab, B. B., Dunham, M. J., & Brown, P. O. (2001) · Genome Biology · doi:10.1186/gb-2001-2-2-research0004 · Cited by 892
Protein microarrays and proteomics
MacBeath, G. (2002) · Nature Genetics · doi:10.1038/ng1037 · Cited by 846
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Protein Microchips: Use for Immunoassay and Enzymatic Reactions
Arenkov, P., Kukhtin, A., Gemmell, A., Voloshchuk, S., Chupeeva, V., & Mirzabekov, A. (2000) · Analytical Biochemistry · doi:10.1006/abio.1999.4363 · Cited by 524
Metadata
- Authors
- Silzel, J. W., Cercek, B., Dodson, C., Tsay, T., & Obremski, R. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-09-01
- Volume
- 44
- Issue
- 9
- Pages
- 2036-2043
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2111987051
- Cited by
- 184
- References
- 5
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.