Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Simultaneous Rapid Measurement of Whole Blood Myoglobin, Creatine Kinase MB, and Cardiac Troponin I by the Triage Cardiac Panel for Detection of Myocardial Infarction

Apple, Fred S, Christenson, Robert H, Valdes, Roland, Andriak, Alexander J, Berg, Amy, Duh, Show-Hong, Feng, Yue-Jin, Jortani, Saeed A, Johnson, Nancy A, Koplen, Brenda, Mascotti, Kristin, Wu, Alan HB·1999·Clinical Chemistry

Abstract

This multicenter study evaluated the Biosite Triage® Cardiac Panel as a quantitative, multimarker, whole blood system for the detection of acute myocardial infarction (MI). Optimum cutoffs for the discrimination of acute MI (n = 192 patients, 59 with MI) as determined by ROC curve analyses were as follows: 0.4 μg/L for cardiac troponin I (cTnI); 4.3 μg/L for the creatine kinase MB isoenzyme (CK-MB); and 107 μg/L for myoglobin. The Triage Panel showed the following concordances for detection or rule-out of MI compared with established devices: cTnI >89%; CK-MB >81%; myoglobin >69%. No significant differences were present between methods for the same marker. Diagnostic efficiencies demonstrated comparable sensitivities and specificities for the diagnosis of MI in patients presenting with symptoms compared with the Dade, Beckman, and Behring CK-MB, cTnI, and myoglobin assays; the ratio of sensitivity to specificity for each marker was as follows: cTnI, 98%:100%; CK-MB, 95%:91%; myoglobin, 81%:92%. The areas under the ROC curves for the Biosite myoglobin, CK-MB, and cTnI were 0.818, 0.905, and 0.970, respectively; the areas were significantly different, P <0.05. In patients with skeletal muscle injury and renal disease, the Triage cTnI showed 94% and 100% specificity, respectively. The Triage panel offers clinicians a whole blood, point-of-care analysis of multiple cardiac markers that provides excellent clinical sensitivity and specificity for the detection of acute MI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/45.2.199

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 187

Metadata

Authors
Apple, F. S., Christenson, R. H., Valdes, R., Andriak, A. J., Berg, A., Duh, S.-H., Feng, Y.-J., Jortani, S. A., Johnson, N. A., Koplen, B., Mascotti, K., & Wu, A. H.
Venue
Clinical Chemistry
Published
1999-02-01
Volume
45
Issue
2
Pages
199-205
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1837514398
Cited by
187
References
1
FWCI
10.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Rapid Measurement of Whole Blood Myoglobin, Creatine Kinase MB, and Cardiac Troponin I by the Triage Cardiac Panel for Detection of Myocardial Infarction. https://app.cochat.ai/papers/10.1093/clinchem/45.2.199
The paper
Apple, F. S., Christenson, R. H., Valdes, R., Andriak, A. J., Berg, A., Duh, S.-H., Feng, Y.-J., Jortani, S. A., Johnson, N. A., Koplen, B., Mascotti, K., & Wu, A. H. (1999). Simultaneous Rapid Measurement of Whole Blood Myoglobin, Creatine Kinase MB, and Cardiac Troponin I by the Triage Cardiac Panel for Detection of Myocardial Infarction. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.2.199

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.