The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Simultaneous Rapid Measurement of Whole Blood Myoglobin, Creatine Kinase MB, and Cardiac Troponin I by the Triage Cardiac Panel for Detection of Myocardial Infarction
Abstract
This multicenter study evaluated the Biosite Triage® Cardiac Panel as a quantitative, multimarker, whole blood system for the detection of acute myocardial infarction (MI). Optimum cutoffs for the discrimination of acute MI (n = 192 patients, 59 with MI) as determined by ROC curve analyses were as follows: 0.4 μg/L for cardiac troponin I (cTnI); 4.3 μg/L for the creatine kinase MB isoenzyme (CK-MB); and 107 μg/L for myoglobin. The Triage Panel showed the following concordances for detection or rule-out of MI compared with established devices: cTnI >89%; CK-MB >81%; myoglobin >69%. No significant differences were present between methods for the same marker. Diagnostic efficiencies demonstrated comparable sensitivities and specificities for the diagnosis of MI in patients presenting with symptoms compared with the Dade, Beckman, and Behring CK-MB, cTnI, and myoglobin assays; the ratio of sensitivity to specificity for each marker was as follows: cTnI, 98%:100%; CK-MB, 95%:91%; myoglobin, 81%:92%. The areas under the ROC curves for the Biosite myoglobin, CK-MB, and cTnI were 0.818, 0.905, and 0.970, respectively; the areas were significantly different, P <0.05. In patients with skeletal muscle injury and renal disease, the Triage cTnI showed 94% and 100% specificity, respectively. The Triage panel offers clinicians a whole blood, point-of-care analysis of multiple cardiac markers that provides excellent clinical sensitivity and specificity for the detection of acute MI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Cited by
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1193 · Cited by 4,487
2014 AHA/ACC Guideline for the Management of Patients With Non–ST-Elevation Acute Coronary Syndromes
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.017 · Cited by 3,595
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181940 · Cited by 1,853
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.013 · Cited by 1,510
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000133 · Cited by 1,254
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000134 · Cited by 1,059
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00889-5 · Cited by 963
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.014 · Cited by 960
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.016 · Cited by 777
Wu, A. H., Apple, F. S., Gibler, W. B., Jesse, R. L., Warshaw, M. M., & Valdes, R. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1104 · Cited by 662
Self-citationWright, R. S., Anderson, J. L., Adams, C. D., Bridges, C. R., Casey, D. E., Ettinger, S. M., Fesmire, F. M., Ganiats, T. G., Jneid, H., Lincoff, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.02.011 · Cited by 516
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
ELISA in the multiplex era: Potentials and pitfalls
Tighe, P. J., Ryder, R. R., Todd, I., & Fairclough, L. C. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400130 · Cited by 464
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318212bb8b · Cited by 343
McCord, J., Nowak, R. M., McCullough, P. A., Foreback, C., Borzak, S., Tokarski, G., Tomlanovich, M. C., Jacobsen, G., & Weaver, W. D. (2001) · Circulation · doi:10.1161/hc3801.096336 · Cited by 297
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
von Lode, P. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.03.008 · Cited by 290
Measurement of Cardiac Troponins
Collinson, P. O., Boa, F. G., & Gaze, D. C. (2001) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320103800501 · Cited by 275
2007 WRITING COMMITTEE MEMBERS, Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828478ac · Cited by 272
Metadata
- Authors
- Apple, F. S., Christenson, R. H., Valdes, R., Andriak, A. J., Berg, A., Duh, S.-H., Feng, Y.-J., Jortani, S. A., Johnson, N. A., Koplen, B., Mascotti, K., & Wu, A. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-02-01
- Volume
- 45
- Issue
- 2
- Pages
- 199-205
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1837514398
- Cited by
- 187
- References
- 1
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.