Pediatric Reference Intervals for Serum Thyroxine, Triiodothyronine, Thyrotropin, and Free Thyroxine
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Thyroid function tests provide information about hormone metabolism and thyroid dysfunction. Reference intervals enable clinicians to evaluate thyroid function. Several pediatric reference intervals for thyroid function tests have been published(1)(2)(3)(4). Laboratory tests and their nomenclature have been published (5), and the American Thyroid Association has classified thyrotropin (TSH) as the best single measurement of thyroid status because of its high sensitivity (6). However, reference intervals that are derived from small numbers of patients are not reliable for accurately evaluating test results that are dependent on covariates such as age and sex. The IFCC has recommended a minimum of 120 subjects for nonparametric methods in which subgrouping of data is performed (7). Virtanen et al. (8) have proposed that a smaller sample size may be sufficient for regression-based reference intervals. Recently, there has been much interest in using hospital databases to extract large volumes of patient data for clinical research(9)(10)(11)(12). Hospital databases provide a sufficient number of subjects for evaluating age and sex differences and for establishing age- and sex-based reference intervals. Test results can be affected by medications or treatment received by patients for thyroid disease that alter the physiologic features of the thyroid hormone concentrations during the neonatal period (13)(14). Therefore, neonates and patients who have thyroid disease or demonstrate abnormal test results should be excluded from the analysis used to establish the reference intervals. Here we report health-related reference intervals for serum thyroxine (T4), triiodothyronine (T3), TSH, and free T4 to be used as clinical guidelines for screening patients with suspected thyroid dysfunction. These pediatric norms are more accurate than those previously published because they are age- and sex-specific and were derived from a large population of children and adolescents. Between January 1993 and August 1996, test results for T4, T3, TSH, and free T4 were obtained retrospectively from outpatient records at Children’s Hospital in Boston for patients 1 month through 20 years of age. Anonymity of patient data was maintained. Medical record number, date of birth, gender, test code, date of test, test result, and International Classification of Diseases (ICD-9) codes were downloaded from the Oracle database on the hospital mainframe computer so that queries could be performed using Paradox (Ver. 5.0; Borland International). ICD-9 codes were used to select patients for the reference group. Excluded diagnoses were hypothyroidism (congenital hypothyroidism; postsurgical and postablative hypothyroidism; iodine hypothyroidism; and iatrogenic, acquired, or unspecified hypothyroidism), hyperthyroidism (toxic diffuse goiter; toxic nodular, uninodular, and multinodular goiter; thyrotoxicosis from ectopic thyroid nodule or other specified origin; thyrotoxicosis with or without storm; and neonatal thyrotoxicosis), and pituitary disorders (acromegaly and gigantism, other anterior pituitary hyperfunction, panhypopituitarism, pituitary dwarfism, diabetes insipidus, disorders of neurohypophysis, iatrogenic pituitary disorders, syndromes of diencephalohypophyseal origin, and dyspituitarism). Infants less than 1 month of age and premature infants were also excluded from analysis. Results from patients who had multiple measurements on the same thyroid function test (<8% for each analyte) were averaged to obtain a single value for each patient in the study. The final sample size consisted of 13 145 test results on 5817 patients (3221 females and 2596 males) after outliers were removed. The total number of patients for each thyroid function test was as follows: T4 (n = 4551), T3 (n = 2683), TSH (n = 5558), and free T4 (n = 353). Measurements of T4, T3, and TSH were obtained with the DELFIA immunofluorometric system according to the manufacturer’s instructions (Wallac Oy). The assay is a solid-phase fluoroimmunoassay that provides a quantitative determination of hormone concentrations in human serum (15). The interassay CV in the euthyroid ranges was <10% for T3 and TSH (16) and 11% for T4 and free T4 (17). A variety of statistical techniques have been proposed to obtain reference limits(7)(8)(11)(18). Some authors have recommended a nonparametric approach for removing possible abnormal laboratory test results by discarding the top and bottom 10% of the results before calculating 2.5% and 97.5% limits on the remaining 80% of the data (19). However, this method can distort the shape of the underlying distribution by cutting off the tails. If outliers that should be removed are not removed, the resulting intervals are too wide and can lead to failure to detect patients with thyroid dysfunction. In this study, we applied a parametric approach to preserve the shape of the distribution. For all four analytes, least-squares regression was performed using
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Use and Misuse of the Sensitive Thyrotropin Assays
NICOLOFF, J. T., & SPENCER, C. A. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-71-3-553 · Cited by 197
Cited by
Hollowell, J. G., Staehling, N. W., Flanders, W. D., Hannon, W. H., Gunter, E. W., Spencer, C. A., & Braverman, L. E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.87.2.489 · Cited by 4,279
Severe hypothyroidism caused by type 3 iodothyronine deiodinase in infantile hemangiomas
Huang, S. A., Tu, H. M., Harney, J. W., Venihaki, M., Butte, A. J., Kozakewich, H. P. W., Fishman, S. J., & Larsen, P. R. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007203430305 · Cited by 540
Kapelari, K., Kirchlechner, C., Högler, W., Schweitzer, K., Virgolini, I., & Moncayo, R. (2008) · BMC Endocrine Disorders · doi:10.1186/1472-6823-8-15 · Cited by 203
Iodine supplementation improves cognition in mildly iodine-deficient children
Gordon, R. C., Rose, M. C., Skeaff, S. A., Gray, A. R., Morgan, K. M., & Ruffman, T. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.28145 · Cited by 193
“6 The normal reference range for 11–15-y-old females is 69–149 nmol/L and for males is 63–147 nmol/L (22).”
Simoneau-Roy, J., Marti, S., Deal, C., Huot, C., Robaey, P., & Van Vliet, G. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.02.021 · Cited by 123
Metadata
- Authors
- Zurakowski, D., Di Canzio, J., & Majzoub, J. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-07-01
- Volume
- 45
- Issue
- 7
- Pages
- 1087-1091
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1840885228
- Cited by
- 88
- References
- 1
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pediatric Reference Intervals for Serum Thyroxine, Triiodothyronine, Thyrotropin, and Free Thyroxine. https://app.cochat.ai/papers/10.1093/clinchem/45.7.1087
- The paper
- Zurakowski, D., Di Canzio, J., & Majzoub, J. A. (1999). Pediatric Reference Intervals for Serum Thyroxine, Triiodothyronine, Thyrotropin, and Free Thyroxine. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.7.1087
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.