Comparison of Plasma Total Homocysteine Measurements in 14 Laboratories: An International Study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Information on interlaboratory variation and especially on methodological differences for plasma total homocysteine is lacking. Methods: We studied 14 laboratories that used eight different method types: HPLC with electrochemical detection (HPLC-ED); HPLC with fluorescence detection (HPLC-FD) further subdivided by type of reducing/derivatizing agent; gas chromatography/mass spectrometry (GC/MS); enzyme immunoassay (EIA); and fluorescence polarization immunoassay (FPIA). Three of these laboratories used two methods. The laboratories participated in a 2-day analysis of 46 plasma samples, 4 additional plasma samples with added homocystine, and 3 plasma quality-control (QC) pools. Results were analyzed for imprecision, recovery, and methodological differences. Results: The mean among-laboratory and among-run within-laboratory imprecision (CV) was 9.3% and 5.6% for plasma samples, 8.8% and 4.9% for samples with added homocystine, and 7.6% and 4.2% for the QC pools, respectively. Difference plots showed values systematically higher than GC/MS for HPLC-ED, HPLC-FD using sodium borohydride/monobromobimane (however, for only one laboratory), and EIA, and lower values for HPLC-FD using trialkylphosphine/4-(aminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole. The two HPLC-FD methods using tris(2-carboxyethyl) phosphine/ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F) or tributyl phosphine/SBD-F, and the FPIA method showed no detectable systematic difference from GC/MS. Conclusions: Among-laboratory variations within one method can exceed among-method variations. Some of the methods tested could be used interchangeably, but there is an urgent need to improve analytical imprecision and to decrease differences among methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194 · cited 1×
“375(CVwithin-subject 2 1 CVbetween-subject (2)) (16).”
Cited by
Biomarkers of Nutrition for Development—Folate Review
Bailey, L. B., Stover, P. J., McNulty, H., Fenech, M. F., Gregory, J. F., Mills, J. L., Pfeiffer, C. M., Fazili, Z., Zhang, M., Ueland, P. M., et al. (2015) · The Journal of Nutrition · doi:10.3945/jn.114.206599 · Cited by 1,136
Self-citationFacts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Stanger, O., Herrmann, W., Pietrzik, K., Fowler, B., Geisel, J., Dierkes, J., & Weger, M. (2003) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2003.214 · Cited by 254
Homocysteine, MTHFR 677C→T polymorphism, and risk of ischemic stroke: Results of a meta-analysis
Fallon, U. B., & Ben-Shlomo, Y. (2003) · Neurology · doi:10.1212/wnl.60.3.526 · Cited by 221
Kuo, H.-K., Bean, J. F., Yen, C.-J., & Leveille, S. G. (2006) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/61.4.380 · Cited by 115
Metadata
- Authors
- Pfeiffer, C. M., Huff, D. L., Smith, S. J., Miller, D. T., & Gunter, E. W.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-08-01
- Volume
- 45
- Issue
- 8
- Pages
- 1261-1268
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2164341995
- Cited by
- 77
- References
- 3
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.