The DOI matches its Crossref record.
Evaluation of DNA Fragment Sizing and Quantification by the Agilent 2100 Bioanalyzer
Abstract
Capillary electrophoresis (CE) achieves efficient separation of molecular species by the application of high voltages to samples in solution (1). Commercial CE units, available for slightly more than a decade, have found numerous applications (2)(3)(4)(5)(6), but are expensive (∼$60 000) and require substantial user training and experience. Recent advances have allowed CE to be performed on microchip devices (7)(8)(9)(10)(11). We evaluated the Agilent 2100 Bioanalyzer (Agilent Technologies), which represents a new generation of CE instruments that use this technology. The Bioanalyzer is relatively inexpensive (∼$18 000) and is simple to operate, requiring only routine pipetting and basic computer skills. Typically, 12 nucleic acid samples can be sized and quantified on a disposable chip within 30 min. Chips are fabricated from glass and comprise an interconnected network of fluid reservoirs and microchannels, which must be filled with a gel-dye mixture. Each chip contains 16 wells: 3 for loading the gel-dye mixture, 1 for a molecular size ladder, and 12 for experimental samples. The movement of nucleic acids through the microchannels is controlled by a series of electrodes, each of which is independently connected to a common power supply. The Bioanalyzer displays data as both migration-time plots and as computer-generated virtual gels. Traditional CE operating variables [temperature, voltage, capillary material, and pH, ionic strength, and viscosity of buffer (12)] cannot be modified. The instruments costs ∼$18 000, and chips cost ∼$12–18 per chip ($1–1.50 per sample).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validation of housekeeping genes for normalizing RNA expression in real-time PCR
Dheda, K., Huggett, J. F., Bustin, S. A., Johnson, M. A., Rook, G., & Zumla, A. (2004) · BioTechniques · doi:10.2144/04371rr03 · Cited by 1,034
Labor-Associated Gene Expression in the Human Uterine Fundus, Lower Segment, and Cervix
Bukowski, R., Hankins, G. D. V., Saade, G. R., Anderson, G. D., & Thornton, S. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030169 · Cited by 77
Metadata
- Authors
- Panaro, N. J., Yuen, P. K. I., Sakazume, T., Fortina, P., Kricka, L. J., & Wilding, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-11-01
- Volume
- 46
- Issue
- 11
- Pages
- 1851-1853
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2124573195
- Cited by
- 189
- References
- 0
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of DNA Fragment Sizing and Quantification by the Agilent 2100 Bioanalyzer. https://app.cochat.ai/papers/10.1093/clinchem/46.11.1851
- The paper
- Panaro, N. J., Yuen, P. K. I., Sakazume, T., Fortina, P., Kricka, L. J., & Wilding, P. (2000). Evaluation of DNA Fragment Sizing and Quantification by the Agilent 2100 Bioanalyzer. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.11.1851
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.