Detection of Multiple Allergen-specific IgEs on Microarrays by Immunoassay with Rolling Circle Amplification
Open accessThe DOI matches its Crossref record.
Abstract
First described in 1967, the radio allergo sorbent test (RAST) has been the standard technique for measuring allergen-specific IgE antibodies in serum (1). An updated version of the RAST test, termed CAP (Pharmacia), has been introduced (2). In clinical practice, CAP results must be interpreted with care. The diagnostic performance of CAP varies in an allergen-specific manner, and CAP scores do not always correlate with clinical severity (3)(4). CAP sensitivity, specificity, and positive predictive values agree well with skin prick tests (SPTs) for house dust mites and grasses, but poorly with tests for cat dander and peanuts (5). Microarray technology potentially offers advantages in diagnostic applications such as allergy testing because the amount of reagent required, and thus the cost per assay, is greatly reduced (6). This approach has been difficult to reduce to practice, however, because the extremely small volumes (∼0.5–5 nL) of sample used to create spots on these microarrays require extremely sensitive methods of analyte detection (7). We have used rolling circle amplification (RCA) (8) for the detection of antibody bound to antigen (9). In this “immunoRCA”, the 5′ end of a RCA primer is attached to an antibody; thus, in the presence of circular DNA, DNA polymerase, and nucleotides, the rolling circle reaction produces a concatamer of circular DNA sequence copies that remain attached to the antibody. The amplified DNA can be detected by hybridization of complementary oligonucleotide probes. ImmunoRCA, therefore, represents a novel approach for signal amplification of antibody-antigen recognition events on microarrays. ImmunoRCA can detect IgE in a format using high-density microarrays of anti-human IgE printed on glass slides by a pin-tool type microarraying robot (9). Here, we describe the production of microarrays of multiple allergens and demonstrate the utility of these microarrays in combination with immunoRCA to simultaneously detect allergen-specific IgEs for multiple allergens in patient samples. We studied a population of 30 patients attending an allergy outpatient clinic (14 males, 16 females; age range, 2–47 years). A standard clinical questionnaire was used, which sought symptoms related to inhaled allergens and exposure to nuts. Skin prick testing was performed with grass pollen (25 g/L), Dermatophagoides pteronyssinus (12 g/L), cat fur (106 QAU/L; Bencard), and peanuts (10 HEP; ALK Soluprick SQ; ALK-Abello A/S). A 10 g/L histamine solution was used as a positive control, with normal saline as a negative control. A standard skin prick technique was used, with weal diameter measured at 15 min. A weal diameter >3 mm was regarded as positive. Allergen-specific IgE was detected in undiluted sera by use of the AutoCAP system (Pharmacia). Results were expressed as class 0–6. Total serum IgE was also measured by the AutoCAP system. For allergen microarrays, extracts of cat hair, house dust mites (D.farinae and D. pteronyssinus), and peanuts (ALK-Abello) were passed over PD-10 columns (Pharmacia) to remove low-molecular weight components and then concentrated by ultrafiltration on Centricon YM-3 filters (Millipore). Spotting of the extracts onto activated glass slides was accomplished using a pin-tool type microarrayer (GeneMachines) as described previously (9). Arrays were blocked with protease-free bovine serum albumin (20 g/L), air-dried, and stored under nitrogen at 4 °C until use. The immunoRCA conjugate consisted of monoclonal anti-human IgE antibody (PharMingen), activated with the heterobifunctional cross-linking agent N-[γ-maleimidobutyryloxy] succinimide ester, conjugated to a 40mer thiolated oligonucleotide primer, and purified as described previously (9). In the immunoRCA method, 10 μL of human serum was added to each array and incubated for 30 min at 37 °C in a humidity chamber. After the arrays were washed twice in phosphate-buffered saline with Tween 20 (0.5 mL/L), the mouse monoclonal anti-IgE antibody DNA conjugate and its complementary circular DNA were applied to each array and incubated at 37 °C for 30 min. RCA was carried out at 37 °C for 30 min, using T7 native DNA polymerase as described previously (9). The RCA product was detected by hybridization with a complementary oligonucleotide labeled with the fluorophore Cy3. Slides were scanned in a General Scanning Luminomics 5000 microarray scanner at a 10-μm resolution with a laser setting of 75 and a photomultiplier tube setting of 65. Mean pixel fluorescence intensity was quantified using the fixed-circle method in the QuantArray software. In a scanning image of an allergen microarray incubated with serum from a patient with multiple allergies (Fig. 1A ), positive signals could be seen from spots of peanut, cat dander, and mite allergens. Signals could also be seen from spots of an oligonucleotide that served as the primer for the circular DNA used in the RCA reaction. The sequence of this primer was the same as the one c
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EAACI Molecular Allergology User's Guide
Matricardi, P. M., Kleine‐Tebbe, J., Hoffmann, H. J., Valenta, R., Hilger, C., Hofmaier, S., Aalberse, R. C., Agache, I., Asero, R., Ballmer‐Weber, B., et al. (2016) · Pediatric Allergy and Immunology · doi:10.1111/pai.12563 · Cited by 932
“(88) spotted a small number of allergen extracts on activated microarray slides and used an interesting rolling DNA circle amplification strategy to detect IgE antibody bound to immobilized allergen.”
BackgroundProtein microarrays and proteomics
MacBeath, G. (2002) · Nature Genetics · doi:10.1038/ng1037 · Cited by 846
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
Self-citationMultiplexed protein profiling on microarrays by rolling-circle amplification
Schweitzer, B., Roberts, S., Grimwade, B., Shao, W., Wang, M., Fu, Q., Shu, Q., Laroche, I., Zhou, Z., Tchernev, V. T., et al. (2002) · Nature Biotechnology · doi:10.1038/nbt0402-359 · Cited by 573
Self-citationPharmaceuticals: a threat to drinking water?
Jones, O. A., Lester, J. N., & Voulvoulis, N. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.02.001 · Cited by 531
Semisynthetic DNA–Protein Conjugates for Biosensing and Nanofabrication
Niemeyer, C. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904930 · Cited by 369
Immuno-PCR: high sensitivity detection of proteins by nucleic acid amplification
Niemeyer, C. M., Adler, M., & Wacker, R. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.02.006 · Cited by 320
EAACI Molecular Allergology User's Guide 2.0
Dramburg, S., Hilger, C., Santos, A. F., de las Vecillas, L., Aalberse, R. C., Acevedo, N., Aglas, L., Altmann, F., Arruda, K. L., Asero, R., et al. (2023) · Pediatric Allergy and Immunology · doi:10.1111/pai.13854 · Cited by 298
Protein microarrays for diagnostic assays
Hartmann, M., Roeraade, J., Stoll, D., Templin, M. F., & Joos, T. O. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2379-z · Cited by 173
Measuring proteins on microarrays
Schweitzer, B., & Kingsmore, S. F. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00278-1 · Cited by 162
Self-citation
Metadata
- Authors
- Wiltshire, S., O’Malley, S., Lambert, J., Kukanskis, K., Edgar, D., Kingsmore, S. F., & Schweitzer, B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-12-01
- Volume
- 46
- Issue
- 12
- Pages
- 1990-1993
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1900145606
- Cited by
- 145
- References
- 0
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.