Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Simple Microplate Method for Determination of Urinary Iodine

Ohashi, Toshinori, Yamaki, Mitsuo, Pandav, Chandrakant S, Karmarkar, Madhu G, Irie, Minoru·2000·Clinical Chemistry

Abstract

Background: Urinary iodine is a good biochemical marker for control of iodine deficiency disorders. Our aim was to develop and validate a simple, rapid, and quantitative method based on the Sandell–Kolthoff reaction, incorporating both the reaction and the digestion process into a microplate format. Methods: Using a specially designed sealing cassette to prevent loss of vapor and cross-contamination among wells, ammonium persulfate digestion was performed in a microplate in an oven at 110 °C for 60 min. After the digestion mixture was transferred to a transparent microplate and the Sandell–Kolthoff reaction was performed at 25 °C for 30 min, urinary iodine was measured by a microplate reader at 405 nm. Results: The mean recovery of iodine added to urine was 98% (range, 89–109%). The theoretical detection limit, defined as 2 SD from the zero calibrator, was 0.11 μmol/L (14 μg/L iodine). The mean intra- and interassay CVs for samples with iodine concentrations of 0.30–3.15 μmol/L were ≤10%. The new method agreed well with the conventional chloric acid digestion method (n = 70; r = 0.991; y = 0.944x + 0.04; Sy|x = 0.10) and with the inductively coupled plasma mass spectrometry method (n = 61; r = 0.979; y = 0.962x + 0.03; Sy|x = 0.20). The agreement was confirmed by difference plots. The distributions of iodine concentrations for samples from endemic areas of iodine deficiency diseases showed similar patterns among the above three methods. Conclusions: Our new method, incorporating the whole process into a microplate format, is readily applicable and allows rapid monitoring of urinary iodine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.4.529

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 255

Metadata

Authors
Ohashi, T., Yamaki, M., Pandav, C. S., Karmarkar, M. G., & Irie, M.
Venue
Clinical Chemistry
Published
2000-04-01
Volume
46
Issue
4
Pages
529-536
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1927243590
Cited by
255
References
7
FWCI
3.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simple Microplate Method for Determination of Urinary Iodine. https://app.cochat.ai/papers/10.1093/clinchem/46.4.529
The paper
Ohashi, T., Yamaki, M., Pandav, C. S., Karmarkar, M. G., & Irie, M. (2000). Simple Microplate Method for Determination of Urinary Iodine. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.4.529

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.