The DOI matches its Crossref record.
Evaluation of a Fully Automated Serum Assay for C-Terminal Cross-Linking Telopeptide of Type I Collagen in Osteoporosis
Open accessAbstract
Background: Biochemical markers of bone turnover can provide prognostic information about the risk of osteoporotic fracture and are useful tools for monitoring efficacy of antiresorptive therapy. A serum-based automated assay may be of better clinical value than urinary markers because of lower imprecision and day-to-day within-person variability. Our aim was to evaluate the technical and clinical performances of a new, fully automated assay for serum C-terminal cross-linking telopeptide of type I collagen (CTX), a marker of bone resorption. Methods: Serum CTX was measured on the Elecsys 2010 automated analyzer (Roche). Results were compared with those of the manual ELISA. We measured serum CTX concentrations in 728 healthy women, ages 31–89 years. We investigated the ability of this assay to predict the rate of postmenopausal forearm bone loss evaluated by four repeated bone mineral density measurements using dual-x-ray absorptiometry in 305 women followed prospectively for 4 years. Finally, in a cohort of healthy, untreated, postmenopausal women, we compared baseline serum CTX in 55 women who subsequently had a fracture (20 vertebral and 35 peripheral fractures) with values in the 380 women who did not fracture during a mean 5 years of follow-up. Results: The within- (n = 21) and between-run (n = 21) CVs were <4.1% and 5.7%, respectively. In 728 healthy women, serum CTX concentrations (automated) correlated with those of the manual ELISA (r = 0.82; P <0.0001). The median long-term within-person variability assessed by four repeated measurements over 3 months in 18 postmenopausal women was 9.4%. Compared with 254 premenopausal women, serum CTX was 39% (P <0.0001) higher in 45 perimenopausal women and 86% (P <0.0001) higher in 429 postmenopausal women (mean age, 64 years). Baseline serum CTX correlated negatively with changes of bone mass measured at the mid (r = −0.23; P <0.0001) and distal (r = −0.27; P <0001) radius. Postmenopausal women with serum CTX greater than the mean + 2 SD values in premenopausal women accounted for 42% of the population, lost bone at the mid radius on average eightfold more rapidly than the other women (−0.27% ± 2.92% vs −2.25% ± 3.95%; P <0.0001), and had increased risk of fracture with a relative risk (95% confidence interval) of 1.8 (1.01–3.1) after adjustment for physical activity. Conclusions: The automated assay for serum CTX is precise and predicts rate of bone loss and fracture risk in postmenopausal women. Because it is convenient to use and has high throughput, this serum bone resorption marker may be useful for the investigation of patients with osteoporosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
for the IOF-IFCC Bone Marker Standards Working Group, Vasikaran, S., Eastell, R., Bruyère, O., Foldes, A. J., Garnero, P., Griesmacher, A., McClung, M., Morris, H. A., Silverman, S., et al. (2011) · Osteoporosis International · doi:10.1007/s00198-010-1501-1 · Cited by 1,212
Self-citationBone Turnover Markers: Basic Biology to Clinical Applications
Schini, M., Vilaca, T., Gossiel, F., Salam, S., & Eastell, R. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac031 · Cited by 387
Hellstein, J. W., Adler, R. A., Edwards, B., Jacobsen, P. L., Kalmar, J. R., Koka, S., Migliorati, C. A., & Ristic, H. (2011) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2011.0108 · Cited by 363
for the National Bone Health Alliance Bone Turnover Marker Project, Szulc, P., Naylor, K., Hoyle, N. R., Eastell, R., & Leary, E. T. (2017) · Osteoporosis International · doi:10.1007/s00198-017-4082-4 · Cited by 327
Biochemical markers of bone turnover – uses and limitations
Hlaing, T. T., & Compston, J. E. (2014) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563213515190 · Cited by 265
Metadata
- Authors
- Garnero, P., Borel, O., & Delmas, P. D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-04-01
- Volume
- 47
- Issue
- 4
- Pages
- 694-702
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1904290160
- Cited by
- 193
- References
- 0
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a Fully Automated Serum Assay for C-Terminal Cross-Linking Telopeptide of Type I Collagen in Osteoporosis. https://app.cochat.ai/papers/10.1093/clinchem/47.4.694
- The paper
- Garnero, P., Borel, O., & Delmas, P. D. (2001). Evaluation of a Fully Automated Serum Assay for C-Terminal Cross-Linking Telopeptide of Type I Collagen in Osteoporosis. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.4.694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.