CoChat

Determination of Blood Total, Reduced, and Oxidized Glutathione in Pediatric Subjects

Open access
Pastore, Anna, Piemonte, Fiorella, Locatelli, Mattia, Lo Russo, Anna, Gaeta, Laura Maria, Tozzi, Giulia, Federici, Giorgio · 2001 · Clinical Chemistry
Cited by 214

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Glutathione (l-γ-glutamyl-l-cysteinylglycine), which is present in virtually all mammalian tissues, provides reducing capacity for several reactions and plays an important role in detoxification of hydrogen peroxide, other peroxides, and free radicals (1). The synthesis and degradation of glutathione are controlled by reactions of the γ-glutamyl cycle; a decrease in blood reduced glutathione (GSH) has been reported in patients affected by deficiencies of the enzymes involved in the synthesis of glutathione (1). In cells, total glutathione can be free or bound to proteins; measurement of free glutathione in blood samples is essential for evaluation of the redox and detoxification status of cells in relation to its protective role against oxidative and free radical-mediated cell injury; moreover, GSH measurement is important for the diagnosis of γ-glutamyl cycle disorders. Recently, several methods to measure glutathione in blood have been described, but little is known about the concentrations of various forms of blood glutathione in pediatric subjects (2)(3)(4)(5)(6). We report a rapid and fully automated HPLC method for determining total (tGSH), reduced (GSH), and oxidized glutathione (GSSG) in whole blood. Moreover, we report values for the different forms of blood glutathione in pediatric subjects. The reference sample group included 227 healthy, randomly selected children who attended the outpatient clinic of our hospital. The children were selected to provide approximately equal numbers of each sex across the age range of 0–15 years. The study was performed according to the recommendations of the Ethics Committee of Children’s Hospital and Research Institute “Bambino Gesù”. Blood was collected into a Vacutainer Tube (Becton Dickinson) containing EDTA. The hemoglobin (Hb) concentration was determined with a hemocytometer, and 100 μL of the blood was immediately mixed with 12 μL of 10 mmol/L phosphate buffer, pH 7.2 (for tGSH and GSH) or with 12 μL of 0.1 mol/L N-ethylmaleimide (NEM; for GSSG). A 100-μL aliquot of each mixture was hemolyzed by adding 900 μL of ice-cold distilled water; 100 μL of each hemolyzed sample was then deproteinized by adding 200 μL of sulfosalicylic acid (120 mL/L), and the glutathione content in the acid-soluble fraction was determined. The derivatization and chromatography procedures were performed, with minor modifications, as reported previously (7). Briefly, the autosampler collected 3 μL of 4 mol/L NaBH4, 2 μL of 2 mmol/L EDTA-dithiothreitol (DTT), 1 μL of 1-octanol, and 2 μL of 1.8 mol/L HCl and placed the mixture in the derivatization vial containing 10 μL of sample and 10 μL of internal standard (50 μmol/L cysteamine). After the mixture was incubated for 3 min, 10 μL of 1.5 mol/L N-ethylmorpholine buffer (pH 8.0), 40 μL of distilled water, and 2 μL of 25 mmol/L bromobimane were added. After an additional 3-min incubation, 4 μL of acetic acid was added, and 40 μL of this mixture was injected into the column. For GSH determinations, NaBH4 was substituted with 2 mmol/L EDTA-DTT. Known concentrations of GSH or GSSG at three different concentrations (100, 500, and 2500 μmol/L) were added to blood samples. The concentrations in samples with added glutathione were determined in five replicates, and analytical recoveries were calculated. The intraassay precision was obtained by analyzing 10 replicates of the biological samples in the same day. The interassay precision was determined by analyzing the same biological samples on 10 different days over 1 month. The CVs for repeatability of sample measurements were 0.5% for tGSH, 7.7% for GSSG, and 1.1% for GSH. The CVs for reproducibility, determined by assaying on 10 different days, were 2.8% for tGSH, 7.9% for GSSG, and 1.8% GSH. The mean recoveries were 89–102.2% for GSH and 96.1–114% for GSSG. Calibration curves for glutathione (5–100 μmol/L glutathione) were prepared in duplicate by diluting the stock solutions with 0.1 mol/L HCl containing 100 μmol/L DTT. The linearity of the assays was also assessed at glutathione concentrations of 0–100 μmol/L. The limit of detection for the calibrators, defined as the concentration that produces a signal-to-noise ratio >5, was ∼50 nmol/L. A linear relationship was obtained between peak area and glutathione concentration in the ranges studied in an aqueous matrix. The correlation coefficient was >0.99. The equation for the regression line (n = 5) was: y = 0.5x + 0.26. The lowest concentrations of the linearity studies were all above the limit of detection of 50 nmol/L. No significant matrix effect was observed when linearity studies were performed in samples diluted up to 1:32 with water containing 100 μmol/L DTT (data not shown). In a typical HPLC-fluorescence detection chromatogram of a sample from a healthy subject (Fig. 1A ), the retention time for glutathione-S-bimane was 4.037 min. The glutathione peak in Fig. 1A was produced by a sample containing 8.6 nmol GSH/mg of Hb. A chromatogra

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.8.1467

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 214

Metadata

Authors
Pastore, A., Piemonte, F., Locatelli, M., Lo Russo, A., Gaeta, L. M., Tozzi, G., & Federici, G.
Venue
Clinical Chemistry
Published
2001-08-01
Volume
47
Issue
8
Pages
1467-1469
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2098529431
Cited by
214
References
1
FWCI
0.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.