Evolution of Methods for Measurement of HDL-Cholesterol: From Ultracentrifugation to Homogeneous Assays
The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Abstract
Background: Adoption of automated homogeneous assays for HDL-cholesterol (HDL-C) is increasing, driven by the need of clinical laboratories to cope with increasing workloads while containing costs. However, performance characteristics of homogeneous assays often differ in important aspects from those of the earlier precipitation methods. This review provides an overview of the new generation of homogeneous assays for HDL-C within the historical context of the evolution of methods and the efforts to standardize measurements of the lipoproteins. Approach: This is a narrative review based on method evaluations conducted in the laboratories of the authors as well as on relevant publications, especially comparative evaluation studies, from the literature. Publications considered here have been collected by the authors over the past 30 years of involvement as methods for HDL-C made the transition from their early use in lipid research laboratories to clinical laboratories and the recent emergence of homogeneous assays. Content: The presentation includes descriptions of methodologies, including homogeneous, precipitation, electrophoresis, and ultracentrifugation assays. Reference methods and recommended approaches for assessing accuracy are described. Accuracy and imprecision are summarized in the context of the National Cholesterol Education Program (NCEP) standards for analytical performance. The effects of interfering substances and preanalytical sources of variation are presented. Summary: Homogeneous assays have been shown to be reasonably well suited for use in routine clinical laboratories, generally meeting the NCEP criteria for precision, accuracy, and total error. However, discrepant results compared with the reference methods have been observed with some of the assays, and the sources of discrepancies are not well characterized. Some homogeneous reagents have not been thoroughly evaluated. At least three of the reagents have experienced successive adjustments in formulation; hence, the reagents may not yet be fully optimized. For these reasons, the homogeneous assays cannot be confidently recommended for use in long-term clinical trials and other research applications without thorough validation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Friedewald, W. T., Levy, R. I., & Fredrickson, D. S. (1972) · Clinical Chemistry · doi:10.1093/clinchem/18.6.499 · Cited by 32,423
Grundy, S. M., Bilheimer, D. W., Chait, A., Clark, L. T., Denke, M. A., Havel, R. J., Hazzard, W. R., Hulley, S. B., Hunninghake, D. B., Kreisberg, R. A., et al. (1993) · JAMA · doi:10.1001/jama.269.23.3015 · Cited by 27,947
Expert Panel on Detection, E. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.19.2486 · Cited by 26,011
National Committee for Clinical Laboratory Standards
Bruck, E. (1980) · Pediatrics · doi:10.1542/peds.65.1.187 · Cited by 14,751
The Metabolic and Molecular Bases of Inherited Disease
Scriver, R. C. (1995) · Medical Entomology and Zoology · Cited by 12,101
Havel, R. J., Eder, H. A., & Bragdon, J. H. (1955) · Journal of Clinical Investigation · doi:10.1172/jci103182 · Cited by 8,760
High-density lipoprotein cholesterol and cardiovascular disease. Four prospective American studies.
Gordon, D. J., Probstfield, J. L., Garrison, R. J., Neaton, J. D., Castelli, W. P., Knoke, J. D., Jacobs, D. R., Bangdiwala, S., & Tyroler, H. A. (1989) · Circulation · doi:10.1161/01.cir.79.1.8 · Cited by 3,162
Abell, L. L., Levy, B. B., Brodie, B. B., & Kendall, F. E. (1952) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)50907-3 · Cited by 3,086
Rapid method for the isolation of lipoproteins from human serum by precipitation with polyanions
BURSTEIN, M., SCHOLNICK, H. R., & MORFIN, R. (1970) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)42943-8 · Cited by 2,491
Goodman, D. S. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.1988.00380010040006 · Cited by 2,246
Cited by
Boekholdt, S. M., Arsenault, B. J., Mora, S., Pedersen, T. R., LaRosa, J. C., Nestel, P. J., Simes, R. J., Durrington, P., Hitman, G. A., Welch, K. M. A., et al. (2012) · JAMA · doi:10.1001/jama.2012.366 · Cited by 795
“Non–HDL-C was calculated as total minus HDL-C.”
ResultLiu, X., Dai, Q., Austin, L., Coutts, J., Knowles, G., Zou, J., Chen, H., & Huo, Q. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711298b · Cited by 675
Rosenson, R. S., Brewer, H. B., Chapman, M. J., Fazio, S., Hussain, M. M., Kontush, A., Krauss, R. M., Otvos, J. D., Remaley, A. T., & Schaefer, E. J. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.155333 · Cited by 511
Nauck, M., Warnick, G. R., & Rifai, N. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.2.236 · Cited by 442
Self-citationMiller, W. G., Myers, G. L., Sakurabayashi, I., Bachmann, L. M., Caudill, S. P., Dziekonski, A., Edwards, S., Kimberly, M. M., Korzun, W. J., Leary, E. T., et al. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.142810 · Cited by 386
Self-citationPathophysiology and types of dyslipidemia in PCOS
Diamanti-Kandarakis, E., Papavassiliou, A. G., Kandarakis, S. A., & Chrousos, G. P. (2007) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2007.07.004 · Cited by 299
HDL cholesterol: reappraisal of its clinical relevance
März, W., Kleber, M. E., Scharnagl, H., Speer, T., Zewinger, S., Ritsch, A., Parhofer, K. G., von Eckardstein, A., Landmesser, U., & Laufs, U. (2017) · Clinical Research in Cardiology · doi:10.1007/s00392-017-1106-1 · Cited by 275
“In the late 1990s, “homogeneous” methods were introduced which allow the measurement of HDL-C in a single reaction vessel with no prior separation steps [17].”
BackgroundShai, I., Rimm, E. B., Hankinson, S. E., Curhan, G., Manson, J. E., Rifai, N., Stampfer, M. J., & Ma, J. (2004) · Circulation · doi:10.1161/01.cir.0000146339.57154.9b · Cited by 236
Self-citationRosenson, R. S., Brewer, H. B., Ansell, B., Barter, P., Chapman, M. J., Heinecke, J. W., Kontush, A., Tall, A. R., & Webb, N. R. (2013) · Circulation · doi:10.1161/circulationaha.113.000962 · Cited by 225
“tion close to 10%(32)) has been reported compared with <4% for analytic measurements.(33) Such variability results from the Table 1.”
BackgroundHigh density lipoproteins: Measurement techniques and potential biomarkers of cardiovascular risk
Hafiane, A., & Genest, J. (2015) · BBA Clinical · doi:10.1016/j.bbacli.2015.01.005 · Cited by 195
“More refined techniques to determine HDL-C in serum include ultracentrifugation (UTC) [23], electrophoresis [24,25], high performance lipoprotein chromatography (HPLC) [26,27], precipitation-based methods [28], direct measuring methods [29,30], and nuclear magnetic resonance (NMR) [31] (Table 2).”
MethodResultDyslipidemia in women with polycystic ovary syndrome
Kim, J. J., & Choi, Y. M. (2013) · Obstetrics & Gynecology Science · doi:10.5468/ogs.2013.56.3.137 · Cited by 190
“HDL encompasses several different classes of lipoproteins (HDL2 and HDL3) according to its density, metabolism and properties [18].”
BackgroundLaboratory Assessment of HDL Heterogeneity and Function
Movva, R., & Rader, D. J. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.101923 · Cited by 188
“The analytical chemistry related to measurement ofHDL-CandHDLsubclasseshasundergonesubstantialevolutionoverthelastfewdecades( 28 , 29).Inlight of recent developments, there is a growing need to identify other HDL-related subclasses and functions, and to find biomarkers that will better predict cardiovascular risk and…”
MethodEffects of Statins on High-Density Lipoproteins: A Potential Contribution to Cardiovascular Benefit
McTaggart, F., & Jones, P. (2008) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-008-6113-z · Cited by 177
“However, questions remain as to the specificity of these assays under contrasting conditions of high and low LDL levels as typically observed in statin trials [25].”
BackgroundFedeli, L. G., Vidigal, P. G., Leite, C. M., Castilhos, C. D., Pimentel, R. A., Maniero, V. C., Mill, J. G., Lotufo, P. A., Pereira, A. C., & Bensenor, I. M. (2013) · Revista de Saúde Pública · doi:10.1590/s0034-8910.2013047003807 · Cited by 159
Charlton-Menys, V., Betteridge, D. J., Colhoun, H., Fuller, J., France, M., Hitman, G. A., Livingstone, S. J., Neil, H. A. W., Newman, C. B., Szarek, M., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.111401 · Cited by 94
Langlois, M. R., Descamps, O. S., van der Laarse, A., Weykamp, C., Baum, H., Pulkki, K., von Eckardstein, A., De Bacquer, D., Borén, J., Wiklund, O., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2013.12.016 · Cited by 72
Metadata
- Authors
- Warnick, G. R., Nauck, M., & Rifai, N.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-09-01
- Volume
- 47
- Issue
- 9
- Pages
- 1579-1596
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2165971695
- Cited by
- 228
- References
- 77
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.